ESFAS Signals Flashcards

1
Q

CIAS setpoints

(2)

Containment Isolation

A

CNTMT #3 psig
PZR #<1837 psia

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

AFAS setpoints

A

S/G level 25.8%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What will start with a AFAS?

A

DG
Sequencer starts:
AFB,
(All DG essentials) EW, SP, EC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

CSAS

A

CNTMT >#8.5 psig

Containment Spray Actuation Signal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What kind of water are we spraying into CNTMT with a CSAS?

A

Borated (tasty haha)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

CSAS - What will start?

A

DG

Sequencer starts:
DG Essentials
CR Essential
FB Essentials

HPSI / LPSI

AF-B
CS
EW
SP
EC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q
A

10 min
have to cross tie EW

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

MSIS setpoints?

A

91% = S/G Narrow range level detector
3# psig = CNTMT pressure
960 psia = S/G pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

RAS setpoints?

A

9.4% = RWT Level

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Plant actions after RAS signal?
(RWT Lvl 9.4%)

A

HPSI/LPSI/CS recirc valves CLOSE.
LPSI stops
CNTMT Sump SI valves OPEN. (SIA-673 & 675)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

SIAS setpoints?

A

1837 psia = PZR lvl
3# psig = CNTMT pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

SIAS plant actions?

A

DGs START
EW, SP, EC STARTS
HPSI / LPSI / CS pumps Start
HPSI / LPSI injection valves open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly