SQ- Radiation Monitoring Flashcards
[SQ]
3 subsystems?
Where is the data sent to?
SRMS / PAMS / DRMS
Safety Related / Post-Accident / Digital Radiation
Display/ Controls: Main CR and RMS/Effluents Office
Data sent to ERFDADS
[SQ]
PAMS purpose?
- Condenser effluent and Plant vent
- Post Accident & Long term monitoring of effluent gases and particulates.
- It informs operators of abnormal radiation in:
containment penetration areas,
main steam line area,
control room and other plant areas
(some are tech spec related)
[SQ]
DRMS purpose?
BOP radiation monitoring system
-Info on process, effluent, and area radiation levels
What types of monitors are used in each of the SQ subsystems?
Quality class QAG monitors
[SQ]
What does SRMS provide? What types of monitors does it use?
ESF Actuation signals
technical specification monitoring and control functions
Contains only quality class Q radiation monitors
[SQ]
Auto Features associated with RU-1?
CTMT Atmosphere Monitor
CIAS - CIVs auto shut to isolate the RU monitor from pressure and temperature transients following a LOCA.
[SQ]
RU-29 and RU-30 Location?
Auto Features?
CR Vent Intake Monitor
- Track noble gas concentrations in the control room air intake.
- HI-Hi Alarm
- CREFAS - activating the CR essential filtration units.
[SQ]
Auto Features RU-145?
PAMS low range monitor
Hi-Hi Alarm
- FEBEVAS (Isolates Normal FB Vent, Starts Essential Ventilation)
- Cross Trips CREFAS
[SQ]
FB Ventilation Exhaust RU Monitor?
FB Actuation Signals?
- 145
- FEBEVAS & CREFAS
[SQ]
RU-37 and RU-38 location?
Auto Features?
[CH] Power Access Purge Monitors
O/S CTMT
- between the power access purge exhaust and refueling purge exhaust ducts
-ESF actuation
high-high alarm CPIAS. This signal cross trips with CREFAS
[SQ] RU-31?
FB Fuel Pool
Hi-Hi (Isolates FB Normal Ventilation, Starts FB Essential)
[SQ] RU-141 Auto Features?
Gland Seal
Monitors for gaseous activity resulting from a primary to secondary leak.
RU-141 is a two channel (141A and 141B) beta scintillation detector.
Channel 141A measures the combined air removal and gland steam flow,
Channel 141B being mounted on the discharge piping of the air removal pumps only.
A high alarm on RU-141A will initiate the operation of the air removal system post filter system.
RU-141B provides alarm function only
In the SQ system, what is the automatic feature associated with Aux. Steam Condensate Receiver Tank Inlet Monitor, RU-7?
Auxiliary steam condensate returning from the boric acid concentrator, LRS evaporator and gas stripper is monitored before it leaves the receiver tank.
High activity alarm is indicative of radioactive leakage into one or more of the process components or improper operation.
Upon high-high alarm the RTI monitor automatically diverts the condensate to the liquid radwaste system
In the SQ system, what is the automatic feature associated with Waste Gas Decay Tank Monitor, RU-12?
to monitor the gross beta radioactivity level in the decay tank discharge header
A high activity alarm provides an indication of an abnormal operating condition, such as, an inadvertent discharge or incorrect valve lineup.
The monitor high-high activity alarm initiates isolation of the decay tank discharge header
How often are the non-tech spec SQ monitors calibrated? What about for the tech. spec ones?
At least every 18 months or following corrective maintenance
weekly, monthly, quarterly are required depending on the montior