Where are the drains that are collected by the RD system sent to for processing, minus the reactor cavity sump and Decon and laundry facility sump?
Liquid Radwaste TDS holdup tanks
The RD system is used to detect leakage from what areas of the plant?
RCS, Refueling Pool, ESF equipment and the Spent Fuel Pool
Lube water to the [RD] sump pumps seals?
DW
What system operates the RD Containment Isolation valves?
Instrument Air
What system supplies power to the Sump Pump motors?
NH
What provides power to the DW solenoid valves supplying cooling water to all the sump pumps?
NK
Where is the RD system vented to?
HR, HA, HS
What is the maximum usable volume in the Reactor Cavity Sump?
520 gallons
Where is the Reactor Cavity Sump vented to?
Containment Building atmosphere
Where is the Reactor Cavity Sump located?
55’ containment building, accessed from the 80’
What are the two Reactor Cavity Sump Pumps rated for?
100% each, delivering 30 gal/min
What is the maximum usable volume of the East and West Containment Sumps? Where are they vented to?
390 gallons
containment building atmosphere
Where is the “overflow” line located in the East/West Containment Sumps? How many pumps are in each sump?
About 3 inches above the hi-hi level
one per sump
The West Containment sump collects what drains through how many penetrations?
One 4” penetration receiving effluent from floor drains, equipment drains, refueling pool and the refueling pool liner plate leak detector compartment
The East Containment sump collects what drains through how many penetrations?
Two penetrations: one is a 4” penetration receiving effluent from floor drains, equipment drains, and the refueling pool and the second is a 2.5” penetration receiving effluent from the Reactor Cavity Sump Pumps
Where are the Containment Radwaste Sumps located?
80’ Containment
What is the capacity of the Containment Sump Pumps?
100% capacity each, capable of delivering 50 gpm
What is the maximum usable volume of the ESF sumps? How many trains of RD ESF drain subsystems are there?
1320 gallons
two, A and B
How many penetrations does each ESF sump have and where do they come from?
Five penetrations
Shutdown cooling heat exchanger room, Containment Spray Pump room, High Pressure Safety Injection Pump room, Low Pressure Safety Injection room, and pipe chase room
Where do the ESF sumps vent to? What type of cover plate do these sumps have?
Aux Building HVAC exhaust duct
gas tight
Where are the ESF sumps located?
40’ Aux building
What lubricates the ESF sump pumps?
DW