PRM (DS 10/22/18) (ER 10/29/18) Flashcards
With a PRM, we only install this keypad.
Zigbee Keypad
Each PRM can support this many zones.
8
List the types of sensors (display icons) that can be programmed to the touchscreen through the PRM
door, window, motion, glass break, smoke, carbon monoxide, environmental, water, panic, duress
Number of PRMs a touchscreen will support.
2
The panic button can be found on this Xfinity Home device.
the Touchscreen
The backup battery used in the PRM.
12 VDC
These are the recommended batteries for our zigbee devices.
Lithium
The range of the resistor value that must be present on a 4 wire smoke detector.
750 ohms- 10k ohms
What PRM stands for.
Panel Replacement Module
Also serves as this to improve the connectivity of the Xfinity Home security system.
Zigbee repeater
The resistor rating required for a 2 wire smoke detector.
2k ohm
The reason Xfinity Home will no longer support legacy wireless sensors.
Legacy wireless security sensors broadcast vulnerable, unencrypted signals.
The type of power supply used for a PRM
12 VDC
Holding this button will enable a chime on a Zigbee Keypad.
8
The duration of the lockout period during PRM power up.
2 minutes
The number of LED lights on the PRM
Three
Designed to save time by eliminating this step.
Programming the panel (Vista 20P)
The specifications for a siren to be compatible.
rated for 12 volts
draw less than 600mA
List the available zone functions that can be programmed to the touchscreen through the PRM
entry/exit, perimeter, 24-hour inform, trouble day/alarm night, silent 24-hour, audible 24-hour, no alarm response, silent burglary
The evaluation should take this amount of time or less.
30 Minutes
Xfinity Home security system provides this type of encryption.
end-to-end
What should be done if wires are not labeled, there is no zones list provided.
Do not perform a takeover
4 wire smoke detectors can not be connected to this zone.
zone 1
The transformer for a PRM must be this if it is dropped from any height.
Replaced
This will be available for replacing a 6160 Alpha Keypad with a Zigbee Keypad.
Zigbee Wallplate
Compared to a CAN, a PRM is this in a size comparison.
Smaller
In order to configure a zone it will need to be this first.
Tripped
All zones can be set to closed by pressing this button on the touchscreen.
Reset All Zones
All zones should be this when pairing a PRM.
Closed
When pairing 2 PRMs, this many can be done at a time.
one
Depending on current draw, the PRM can support how many 2 wire smoke detectors.
Up to 16
The Xfinity Home security system includes these components.
3 door sensors, 1 motion, 1 keypad, 1 touchscreen
How many keypads may we give the customer when installing a PRM
up to Two
A PRM will not support this type of smoke detector configuration.
mixed and matched
When installing a PRM, the legacy system does not have to be BLANK but it must be BLANK before the install proceeds.
Powered up. Tested.
The types of smoke detectors that a PRM supports.
2 wire and 4 wire
Sensors wired in series will appear as this on the touchscreen
one zone
This matters when connecting the power supply to the PRM
Polarity
The information required to access settings on the touchscreen.
the technician code, premise pass phrase
Type of sensors that can be used on zone 1.
all except 4-wire smoke.
Zone 1 must be enabled for this.
Trip to pair
The audible device in the home must be this in order to function properly.
a siren
A legacy keypad requires this button sequence.
code then command
Do not place the PRM here.
In the existing enclosure.
The number of keypads we may give the customer in the New England Division
one
The Zigbee Keypad does not have this function.
Panic Button
Max current allowed form the AUX Power terminals.
600 mA
Wires for legacy keypads should be capped and labeled this.
for future use
The PRM will do this when it is in pairing mode.
The LED will flash green 3 times every 5 seconds.
A 2 wire smoke must be wired to this zone
zone 1
A 4 wire smoke will initially enroll as this
a door window
The power supply can support this many PRMs via daisy chain.
2
The maximum distance allowed between power supply and control for guage
a) 22
b) 20
c) 18
a) up to 20 feet
b) up to 30 feet
c) up to 50 feet
The second PRM in will not support these devices.
powered zones
smoke detectors
sirens
Each zone should take this long to evaluate.
2 minutes
How long will PRM stay in pairing mode?
20 minutes
The PRM will communicate with what two touchscreens?
TCA-203 and TCA-300
Both signal strength numbers for the PRM should read between _ and _ on the Touchscreen
0 and -65
How much does a PRM weigh? (including battery)
6 lbs
Operating temperature of a PRM
32 degrees F to 122 degrees F
max wire length for use with a PRM
1000 feet
Minimum Wire Gauge for use with PRM
22 AWG
Model Number of PRM control panel
REHP1AZ0
Three lights on upper right corner of control panel from top to bottom
Power
Low BATT
Pair
First four labeled pairs of screws on PRM Control Panel
12 VDC INPUT, SIREN, SMOKE POWER, AUX POWER
zones 1 through 8 screw terminal labels in order from left to right.
Z1+, Z1-, GND, Z2, Z3, GND, Z4, Z5, GND, Z6, Z7, GND, Z8