What pressure is natural gas piped in med to high pressure?
Low pressure in to domestic property?
High-med 85 - 25 bar
Low pressure 1 bar
What are the cordons related to natural gas leaks?
Domestic
Ruptured high/med pressure pipeline or building filled with gas
Ruptured high/med where the gas jet through congested regions
Mass release of bulk storage of natural gas
Domestic 25m
Ruptured high/med pressure pipeline or building filled with gas - 200m
Ruptured high/med where the gas jet through congested regions - 600m
Mass release of bulk storage of natural gas - 1000m
What is mixed with natural gas at local distribution centre? And why?
Ethyl mercaptan (stenching agent) so that it can readily detected by smell
How long may it take to isolate the high pressure gas supply?
Could take up to a hour as it has to be stage down.
Which is heavier air or carbon monoxide?
About the same density. There for in a leak it has the potential to contaminate all adjoining rooms.
Wind direction are always quoted as?
Coming from!!
One pump is the PDA for a natural gas leak. At what distance should the appliance park away from the leak?
25m
And siting of the appliance should be more 45% from the front and rear doors
Why would it be obvious that a high pressure natural gas pipeline has ruptured?
From the noise. A minimum 200m cordon should be in place.
Can crews go into shut off a gas supply?
Yes, but only where they are not put at risk of gas explosion. They must wear BA and only use barie as hand held are not intrinsically safe.
The responsibility for safety of the gas supply rest with the GA
Tag form 5288 left
Where a gas leak has been ignited, should it be extinguished?
No it shouldn’t be extinguished but the surrounding risks should be protected by lashing off jets and evacuating the area until the gas supply has isolated.
Does the LFB have powers to gain entry at gas leak incidents for purposes of securing the gas supply?
No but the gas authority do. LFB should not gain entry on behalf of the gas authority unless there is an exceptional public safety issue
Can the gas authority request that the LFB remain on site to provide cover for the gas authorities workforce?
Crews should only remain on site for public safety. The gas ask for protection this has to be agree by the DAC and may be chargeable.
Fitting and services should not be used when sending messages regarding utilities. Why is this? And what should be sent instead?
To safe confusion. The word apparatus should be used.
When brigade inform the GA what information needs to be passed on?
3
- inside or outside (Will send different teams)
- the size of the fire
- whether injuries have been sustained
At a gas related incident who is responsible for the safety of any one working at the incident?
The IC is responsible while they are still in attendance.