Natural Gas And Carbon Mon Flashcards

1
Q

What pressure is natural gas piped in med to high pressure?

Low pressure in to domestic property?

A

High-med 85 - 25 bar

Low pressure 1 bar

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are the cordons related to natural gas leaks?

Domestic

Ruptured high/med pressure pipeline or building filled with gas

Ruptured high/med where the gas jet through congested regions

Mass release of bulk storage of natural gas

A

Domestic 25m

Ruptured high/med pressure pipeline or building filled with gas - 200m

Ruptured high/med where the gas jet through congested regions - 600m

Mass release of bulk storage of natural gas - 1000m

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is mixed with natural gas at local distribution centre? And why?

A

Ethyl mercaptan (stenching agent) so that it can readily detected by smell

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How long may it take to isolate the high pressure gas supply?

A

Could take up to a hour as it has to be stage down.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Which is heavier air or carbon monoxide?

A

About the same density. There for in a leak it has the potential to contaminate all adjoining rooms.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Wind direction are always quoted as?

A

Coming from!!

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

One pump is the PDA for a natural gas leak. At what distance should the appliance park away from the leak?

A

25m

And siting of the appliance should be more 45% from the front and rear doors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Why would it be obvious that a high pressure natural gas pipeline has ruptured?

A

From the noise. A minimum 200m cordon should be in place.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Can crews go into shut off a gas supply?

A

Yes, but only where they are not put at risk of gas explosion. They must wear BA and only use barie as hand held are not intrinsically safe.

The responsibility for safety of the gas supply rest with the GA

Tag form 5288 left

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Where a gas leak has been ignited, should it be extinguished?

A

No it shouldn’t be extinguished but the surrounding risks should be protected by lashing off jets and evacuating the area until the gas supply has isolated.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Does the LFB have powers to gain entry at gas leak incidents for purposes of securing the gas supply?

A

No but the gas authority do. LFB should not gain entry on behalf of the gas authority unless there is an exceptional public safety issue

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Can the gas authority request that the LFB remain on site to provide cover for the gas authorities workforce?

A

Crews should only remain on site for public safety. The gas ask for protection this has to be agree by the DAC and may be chargeable.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Fitting and services should not be used when sending messages regarding utilities. Why is this? And what should be sent instead?

A

To safe confusion. The word apparatus should be used.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

When brigade inform the GA what information needs to be passed on?

3

A
  • inside or outside (Will send different teams)
  • the size of the fire
  • whether injuries have been sustained
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

At a gas related incident who is responsible for the safety of any one working at the incident?

A

The IC is responsible while they are still in attendance.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Can the detection equipment used by GA be relied upon if crews are to be committed

A

No. FRU, RRT, fire investigation