SYSTEMS PC-12 Flashcards
WHAT SETS OF THE PUSHER AND SHAKER
EACH COMPUTER CAN ACTIVATE THE SHAKER
BUT BOTH COMPUTERS MUST AGREE BEFORE THE PUSHER IS ACTIVATED
STICK SKAKER PUSHER
USES 2 COMPUTERS
A LEFT AND RIGHT HAND COMPUTER
EACH COMPUTER RUNS OF INPUT SIGNALS FROM ITS ASSOCIATED AOA SENSER AND AIR TO GROUND SQUAT SWITCH
WHEN DOES THE SHAKER PUSHER BECOMES ACTIVE ?
THE SHAKER BECOMES ACTIVE RIGHT AFTER LIFT OFF
THE PUSHER BECOMES ACTIVE 5 SECONDS AND DEACTIVATES ABOVE 163KIAS
WHAT IF THE PUSHER CANNOT BE TESTED ON THE GROUND ?
MAINTENANCE MUST BE CALLED AND TAKE OFF IS NOT PERMITTED
WHAT IS PUSHER ICE MODE ?
WHEN PROP DEICE AND SEPARATOR ARE ACTIVE
[PUSHER ICE MODE]
THE ANGLES OF ATTACK DEFINED ARE REDUCED BY 8 DEGREES
ELECTRICAL SYSTEM
28 VDC SYSTEM BATTERY IS 24 VDC IN THE EVENT OF A DUAL GEN FAILURE THE BATERY CAN SUPPLY POWER AT 20MIN AT 60 AMPS 30MIN AT 50 AMPS
GEN 1
FUNCTIONS TO TURN THE ENGINE DURING STARTING SEQUENCE
PRIMARY SPURCE FOR 28 VDC WHEN THE ENGINE IS RUNNING.
HOW MANY LOADS CAN GEN 1 SUPPLY ?
MAXIMUM LOAD OF 300AMPS WITH A 450 LOAD PERMISSIBLE FOR 2 MINUTES FOR EACH HOUR OF OPERATION
CAN GEN 1 SUPPLY THE WHOLE AIRCRAFTS ELECTRICAL SYSTEM ?
.
HOW DOES THE PC 12 PREVENT OVER HEATING OF THE GENS ?
THERES AN AIR FOW COOLING DUCT ON THE LEFT SIDE OF THE ENGINE COWLING
INVERTERS
THEY FUNCTION TO ONVERT 28VDC TO 26VAC
WHAT ARE THE ESSENTIAL BUSSES ?
THE GEN BUS THE GEN 2 BUS AND THE BATTER BUS
THE [ESSENTIAL BUS CAWS] COMES ON WHEN THE VOLTS DROP BELOW 18V
EXTERNAL POWER SYSTEM
GPU MUST PROVIDE 27-30VDC AT A MIN OF 500AMPS FOR ALL ELECTRICAL-POWERED SYSTEMS.
WHAT IS THE MIN VOTLS FOR A BATTERY START AND OR A GPU START ?
24V FOR A BATTERY START
20V FOR A GPU START
DESCRIBE THE POWER LIINE WHEN THE ENGINE IS RUNNING AND THE GENS ARE BOTH ON LIINE
THE BUS TIE IS CLOSED
THE GEN 2 IS OPEN
GEN 1 POWERS EVERYTHING EXEPT THE GEN 2