A-CAUTION PANEL Flashcards
#1 or #2 STALL SYST FAIL
These caution lights come on in flight, when a malfunction that prevents stick shaker and pusher operations are sensed
ROLL SPLR
INBD GRND
FCECU is not able to control the inboard spoiler lift dump operation. The inboard spoilers do not extend at touchdown or the inboard spoilers extend after the TAXI mode selection after touchdown.
FLIGHT DATA
RECORDER
This caution light comes you do the FDR test, if the light comes stays on then the FDR test has failed.
ELEVATOR
FEEL
One of the FCECU channels is not able to control the pitch feel actuator or acceleration 1 and 2 mismatch. Airspeed 1 and 2 mismatch (RUD PRESS, SPLR OUTBD, and PITCH TRIM caution lights will also come on).
R AC BUS
AC GENS are protected from bus faults by their respective GCU’s. The GCU detects an excessive load and the GCU isolates the affected BUS and the R AC BUS illuminates.
PITOT
HEAT 1
PITOT
HEAT 2
PITOT
HEAT STBY
These caution lights come on when the related probe has malfunction and or the switch is tuned off
ELEVATOR TRIM
SHUTT OFF
PUSH OFF SWITCH ON THE GLARE SHIELD
The switch has failed or the elevator trim switch is pressed for more then 3 seconds
ICE DETECT
FAIL
Both de ice probes have failed
FLT COMPT
DUCT HOT
Flight compartment supply duct’s temperature is 88C for 190F
PITCH
TRIM
(2)
- One of the FCECU channels is not able to control its related pitch trim actuator.
- Or the pilot and co pilots trim are different
L AC BUS
Left AC bus fault is sensed and the GCU has isolated it
#1 HYD ISO VLV
1 HYD ISO VLV is closed.
- ANTI SKIDS ( BREAKA )
- INBORD SPOILER
1 PEC
1 Propeller Electronic Controller Malfunction
If the #1 PEC and the associated prop is above 1020rpm then its a prop over speed and vitals apply
#1 ENG FUEL PRESS
Pressure at the engine driven #1 inlet is low or below a preset value
#2 ENG FUEL PRESS
Pressure at the engine driven #1 inlet is low or below a preset value
2 PEC
2 Propeller Electronic Controller Malfunction
If the #1 PEC and the associated prop is above 1020rpm then its a prop over speed and vitals apply
CABIN
DUCT HOT
Cabin supply duct
temperature is 88 deg
C(190 deg F).
#2 HYD ISO VLV
No. 2 isolation valve
is closed.
All you have left is ( RE )
- Rudder ( Upper PTU )
- Elevator
#2 BLEED HOT
No. 2 bleed air supply
duct temperature is hot,
or duct overpressure or
duct leak.
#1 BLEED HOT
No. 1 bleed air supply
duct temperature is hot,
or duct overpressure or
duct leak.
#2 ENG HYD PUMP
No. 2 Engine Driven Hydraulic Pump pressure is low or the condition lever is set to the FUEL OFF position.
#1ENG HYD PUMP
No. 1 Engine Driven Hydraulic Pump pressure is low or the condition lever is set to the FUEL OFF position.
#1 STBY HYD PUMP HOT
The temperature of the electric motor windings on the No. 1 standby hydraulic pump is too hot.
SPLR
OUTBD
FCECU has failed to inhibit outboard spoiler pressure at greater than 170 KIAS or has failed to re-enable below 165 KIAS.
The FCECU fails to lockout outboard spoilers when airspeed > 185 KIAS, or fails to enable below 150 KIAS,
• Airspeed # 1 is not equal to Airspeed # 2 ± 17 kt (IAS MISMATCH message on PFD, RUD CTRL, ELEVFEEL and PITCH TRIM caution lights also turn on),
#2 STALL SYST FAIL
No. 2 stall warning
system malfunction, or
a loss of a valid AOA
parameter.
GPWS
Ground Proximity Warning System (GPWS) has malfunctioned or there is an RA failure.
ELEVATOR
ASYMMETRY
Right and Left elevators have a difference in angle of 4° for IAS > 185 KIAS and 6° for IAS < 185 KIAS.
DC BUS
EPCU has reconfigured the main 28 VDC generation sytem because of a source or bus fault condition.
ENG ADPT
HEAT 1
Malfunction of both
No. 1 air intake heating
elements.
ENG ADPT
HEAT 2
Malfunction of both
No. 2 air intake heating
elements.
CABIN
PACK HOT
Right Air Cycle Machine
(ACM) discharge
temperature is hot.
STBY
BATTERY
Standby battery is not
connected to its main
feeder bus for charging.
#2 DC GEN HOT
No. 2 DC generator
temperature is hot.
#1 DC GEN HOT
No. 1 DC generator
temperature is hot.
1 DC GEN
No. 1 DC generator is not connected to its bus because of a source fault condition. The DC GEN 1 toggle switch is set to the OFF position, or the external DC power is energizing the left and right main feeder busses.
2 DC GEN
No. 2 DC generator is not connected to its bus because of a source fault condition. The DC GEN 2 toggle switch is set to the OFF position, or the external DC power is energizing the left and right main feeder busses.
PUSHER
SYST FAIL
Stick pusher inhibited by
SPS logic, or stick pusher
SHUT OFF Switchlight
pushed.