Q-ICE PROTECTION Flashcards

0
Q

How long does each boot cycle for in the automatic mode ?

A

6 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

How many boot cycles are there ?

A

6

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How long is the dwell time during automatic mode in fast / slow ?

A

24 seconds in fast mode

3 min/ 144 in slow mode

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What does the manual mode selection do on the airframe mode select selector ?

A

it manually heats up the DDV and the check valve heaters ( dual distributer valves )

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Will the airframe manual mode work if if the airframe mode selector is not in the manual mode ?

A

No airframe mode selector must be off or in manual.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the indication of a leak in the pneumatic de-ice system ?

A

DE-ICE PRESS caution lights or de-ice pressure drops below 15 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When do the ice-detecton probes give an ICE-DETECTION message ?

A

when they accumulate enough ice to change the vibration pattern

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

How are the AOA vanes heated ?

A

Electrically automatically via AC power

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

When do the pitot heat caution lights come on ?

A

when they are off

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What does INCREASE REF speed switch do ?

A

during icing it will increase Vref by 20 knots to help compensate for the condition
and the Low speed Cue increases

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is the minimum oil temperature for inlet-splitter de-icing ?

A

65 degrees in flight within 3 minutes

55 degrees required for take off

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What conditions must be met for the engine intake adapter heaters to turn on ?

A

Bypass doors open
Temp less then +15
Engine oil with normal range

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What happens if one of the intake adapter heaters coils fail ?

A

No indication unless both the primary and secondary fails

you get the ENG ADP HEAT 1 or 2 caution panel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

How much ice must accumulate for the ICE DETECTED message to aluminate ?

A

0.5 MM of ice on the probes.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

On the prop selector switch, what must be met for the prop heat test when selected to test ?

A

Np must above 400 rpm

AC power available.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What controls the prop heaters ?

A

The timer monitor control unit. ( TMCU )

16
Q

What’s the min temp for the TMCU to activate the heaters with corresponding TAT ?

A

Less then 5 degrees.

17
Q

What does ICE DETECT FAIL indicate ?

A

Both ice detector probes have failed.

18
Q

Will a failure of one Ice detector probe cause a DEICE fail caution ?

A

No only when two have failed.

19
Q

What is the isolation valve in the DEICE system ?

A

A valve that is normally open for uninterrupted flow to both pneumatic system.
The switch can be used to check pressure on either side.
It can be closed to isolate a leak on one Side.

20
Q

If the TMU temperature monitor fails, will the DDV heater stay on ?

A

Yes by default.

21
Q

If the TMU heater activation fails, will the DDV heaters come on automatically ?

A

No

22
Q

What happens if the TMU fails ?

A

A DE-ICE TIMER caution light

23
Q

When does the DEICE PRESS caution light come on ?

A

When the main DEICE pressure is less then 15 psi
Boot pressure does not reach 15 psi after DDV are open
Boot pressure remains at 15psi after DDV closes.

24
Q

fast

A

1 min

24 sec dwell

25
Q

slow

A

3 min

dwell time 2min +24

26
Q

prop heat operation in flight ?

A

.

27
Q

alpha vane heaters

A

AOA 115VAC

28
Q

ED message of the ICE DETECTED , is it steady or flashing ?

A

flashing