FWP & FWPT Lube Oil Flashcards
Describe the AC powered lube oil pumps.
4 stage dual discharge pumps
What does the FWP / FWPT lube oil system supply?
Oil to bearings on the pump and turbine and control oil to the turbine control system.
What does the DC emergency lube oil pump supply?
It only supplies oil to the bearings, NOT the control oil system
What major components make up the FWPT FWP lube oil system?
Oil reservoir Main oil pumps Emergency lube oil pump Oil coolers Vapor extractor Oil separator Servo filter
Where are the lube oil pumps located?
In the reservoir with the motors mounted on top of the reservoir.
What does the low pressure discharge of the lube oil pump supply?
Pump and turbine bearings
What will cause the second FWP FWPT main lube oil pump to start?
Low header pressure will start the standby pump if it’s in auto.
There is also a test push button locally and in the control room
Same for ELOP
What cools the FWP FWPT lube oil coolers?
TC with one cooler in service at a time.
What automatic feature is associated with the lube oil filters?
There is an automatic bypass feature that prevents a filter from shutting off oil to the bearings due to clogging
How many vapor extractors are there?
2, one for each feed pump.