What components make up the aux steam receiver package?
a receiver, vent condenser, and two aux steam condensate receiver transfer pumps
What supplies cooling to the vent condenser?
NC
Where does the discharge of the aux steam condensate receiver transfer pumps go?
either to the LRS low TDS holdup tank if radiation is detected or to the condenser
What are the pressures of the 3 reducing stations in the aux steam system?
1150 psig to 250 psig
250 psig to 50 psig
250 psig to 52.3 psig
which RU monitor detects radiation in the aux steam condensate?
RU-7
How do ASN-RV-11A/11B fail on a loss of IA?
11A fails closed, 11B fails open (all flow to the LRS)
What happens to PV-331 & 332 on a pressure of 1 psig in the aux building, CST pipe tunnel, or HUT tunnel?
the valves will trip shut . When the overpressure situation has been corrected, the valves must be manually reset.
Trash can valves
What are the modes of operation of the condensate receiver transfer pumps?
stop/start/auto.
auto will alternate the lead pump on high level in the receiver tank
What are the loads off the 50 psig regulator in the aux steam system?
gas stripper, BAC, and LRS evaporator
What are the loads off the 250 psig regulator in the aux steam system?
the two smaller regulators/reducers MFWP turbines for o/s testing heater 4 for startup fw heating gland sealing steam AFP turbine for o/s testing blow down stack cross tie header