State the purpose of Aux Feed (AF).
1) Provide independent means of feeding steam generators during normal shutdown, startup, and emergency or accident conditions.
What is the basis for the AF water reserve?
Provides enough feedwater to permit the plant to operate in hot standby (mode 3) for 8 hrs followed by an orderly plant cool down at a rate NTE 75F/Hr to the point where shutdown cooling may be placed in operation (RCS <350F).
Draw AF.
Include all sources, valves, pumps, and discharge paths for all 3 AF pumps.
Where can AF pump recirc flow be aligned to?
the CST only. If taking a suction of the RMWT, then there is potential for radiological contamination of the CST.
What cools the AF pump rooms?
A & B are normally cooled by Aux bldg normal AHUs when they are in standby. Once started, they will be cooled by EC.
The N pump is in the turbine building, so no cooling is provided other than HT.
Where does the Secondary Chemical Control system inject ammonia and hydrazine to?
the suction of AFN-P01.
What is the power supply to AFN?
PBA-s03
What is the power supply to all of the “B” train motor operated valves?
PH
What are the steam supplies to AFA-P01?
Aux steam (overspeed uncoupled testing only) SG
Where do the drains for the AF pump rooms go?
Radioactive Waste Drains (RD). It can handle 200GPM from the rooms.
What cools AFN-P01 oil coolers?
The oil is cooled by a slipstream of water from the pump first stage discharge.
What are the sources of control power for AFN-P01 and how do you select which is to be used?
PKA and the A train class battery charger. There is a 3 position transfer switch located near PBA-S03.
How does feed water get from AFN-P01 to the S/G?
through the downcomer control valves or the downcomer control valve bypass valves
What position are the valves for the AFN pump suction usually in?
closed to protect the CST volume from a pipe shear in the non-seismic portion of the system.
What interlock is associated with the AFN pump suction valves?
When valves are < 80% open the AFP won’t start and if it’s running, it will trip the pump if the valves go closed