ETHICS - BP 220: Revised Economic and Socialized Housing Projects Flashcards
ceiling height; measurement for headroom shall be provided
minimum of 2.0 meters
ceiling height; measurement for headroom for mezzanine floors
not less than 1.80 meters
doors; minimum clear height shall be provided
minimum of 2.0 meters
doors; measurement for bathroom, and mezzanine door height must have a _____________
minimum of 1.8 meters
doors; measurement for the minimum width of main doors
0.80 meters
doors; measurement for the minimum width of service/bedroom doors
0.70 meters
doors; measurement for the minimum width of bathroom doors
0.60 meters
stairs; minimum measurement of width for stairs
0.60 meters
stairs; maximum riser height
0.25 meters
stairs; minimum tread width
0.20 meters
stairs; minimum headroom clearance
2.0 meters
stairs; maximum height between landings
3.60 meters
stairs; minimum handrail height
0.80 meters
stairs; maximum handrail height
1.20 meters
stairs; minimum clearance of handrail from the wall
0.033 meters or 33 mm