Electrical CBT's Flashcards
What does the single synchronous bus do?
It keeps all electrical busses powered even when IDG’s or other sources may be down. (tie bus).
How many APU’s? GPU’s?
1 APU (2 APU generators)
2 GPU’s
How many TRU’s?
4
Each IDG normally powers____
its relative AC bus
Can APU electrical be used in flight?
No
Can you reconnect an IDG after disconnecting it?
No, only MX can on the ground.
Can 1 IDG (or 1 APU/GPU) source be enough to power the entire electrical system?
Yes
Does the 747 have no-break power source meshing by matching voltage and frequency momentarily before switching?
Yes
What is a GCB?
Generator Control Breaker. (OFF for IDG. Just above the IDG disconnect button.)
What causes the EICAS message: ELECTRIC DRIVE (1) (2) (3) or (4)
-High Oil Temp
-Low Oil Pressure
-Uncorrectable Frequency Fault
What condition automatically disconnects an IDG?
High IDG Oil Temperature
What items are on the main deck cargo handling bus?
-Main Deck Cargo Handling Equipment and lights
-Nose and Side Cargo Doors
What items are on the ground service bus?
· battery chargers
· Fuel pumps for APU start
· Flight deck flood and service lights
Nav lights
· Miscellaneous service outlets and
equipment
What powers the Captain transfer bus? FO transfer bus? What is the backup?
CA: AC Bus 3
FO: AC Bus 2
Common backup: AC Bus 1
What is an ELCU?
Electrical Load Control Unit.
They are on each utility bus and protect the system against utility faults by load shedding.