BISP CH 5 REF 3.1 Flashcards

1
Q

WHAT IS R-1 OCCUPANCY

A

HOTELS

MOTELS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

WHAT IS R-2 OCCUPANCY

A

MULTIPLE DWELLINGS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

WHAT IS R-3 OCCUPANCY

A

PRIVATE DWELLINGS ONE AND TWO FAMILY

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

LOCATION OF SMOKE DETECTOR IN THE 2008 BUILDING CODE

A
  • ON THE CEILING OR WALL OUTSIDE OF EACH ROOM USED FOR SLEEPING PURPOSES WITHIN 15 FEET FROM THE DOOR TO SUCH ROOM
  • IN EACH ROOM USED FOR SLEEPING
  • EACH STORY OF THE DWELLING UNIT
  • INCLUDING BELOW GRADE AREAS AND PENTHOUSES BUT NOT INCLUDING CRAWL SPACES OR UNINHABITABLE ATTICS
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

SPLIT LEVEL DWELLINGS

A

IF THERE IS NO INTERVENING DOORS BETWEEN THE ADJACENT LEVELS A SMOKE ALARM INSTALLED ON THE UPPER LEVEL SHALL SUFFICE FOR THE ADJACENT LOWER LEVEL PROVIDED THAT THE LOWER LEVEL IS LESS THAN ONE FULL STORY BELOW THE UPPER LEVEL

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

POWER SOURCE 2008 BUILDING CODE

A

DEDICATED BRANCH OR AN UNSWITCHED PORTION OF A BRANCH AND SHALL BE EQUIPPED WITH A BATTERY BACKUP. SMOKE ALARMS SHALL EMIT A SIGNAL WHEN THE BATTERY IS LOW. WIRES SHALL BE PERMANENT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

INTERCONNECTED ALARMS

A
  • ALL SMOKE IN R-2 AND R-3

* IN R-1 JUST CONNECTED WITHIN THE UNIT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

PUBLIC HALL SMOKE DETECTORS

A

R-1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

J-2 MULTIPLE DWELLING OLD CODE

A
  • OWNER PROVIDE AND INSTALL REQ DETECTORS
  • POST A NOTICE IN LOBBY
  • OCCUPANT RESPONSIBLE FOR REPAIR AND MAINTENANCE
  • OCCUPANT MUST REPLACE IF NEEDED
  • IF INOPERABLE WITHIN 1ST YEAR OWNER MUST REPLACE WITHIN 30 DAYS
  • OWNER MUST KEEP RECORDS
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

ABSENT OR DEFECTIVE SMOKE DETECTING DEVICES FOUND DURING INSPECTION, FIRE OR EMERGENCIES

A
  • FORWARD AN A-8B IN DUPLICATE

* PHONE NOTIFICATION NOT REQUIRED

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

WRITTEN NOTIFICATION RECEIVED

A

FORWARD TO FPCU

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

VERBAL COMPLAINT

A

TELL THEM TO CALL DEPARTMENT OF HOUSING BY DIALING 311

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

FATAL FIRE AND MISSING SMOKE DETECTOR

A

DC WILL MAKE AN ENTRY ON THE FATAL FIRE REPORT AND THEN DIRECT THE ADMIN COMPANY TO FORWARD AN A-8B TO FPCU

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

IF REQUIRED SMOKE DETECTOR FOUND AT A FATAL FIRE

A
  • THE DC WILL ENTER THE BRAND AND MODEL NUMBER ON THE FATAL FIRE REPORT
  • PHONE NOTIFICATION NOT REQUIRED
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Ceiling mounted smoke detectors

A

Closest edge a minimum of 4 inches from any wall

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Wall mounted smoke detectors (1968 building code)

A

Closest edge of the smoke detector shall be a minimum of 4 inches and a maximum of 12 inches from the ceiling

17
Q

In a basic 2 story 3 bedroom home, how many smoke detectors are needed

A

Six
One in each bedroom (3)
One in hallway to all rooms within 15 feet of the doors. If the hallway is only 15 feet long than (1) smoke detector is needed
In each story of the house including basements and penthouses
Do not need in uninhabitable areas including crawl spaces