AOP-5 "Control Rod Drop" Flashcards
1
Q
AOP-5 entry conditions
A
- EK-0948 “Dropped Rod” AND any rod bottom limit switch AND dropped rod indication on PPC page 410
- Misaligned control rod (greater than 19”)
- Uncoupled control rod
- Reactor Engineering discretion
2
Q
AOP-5 automatic actions
A
Possible TM/LP or VHPT trip
3
Q
AOP-5 reactor trip criteria
A
- 1 or more dropped or misaligned rod with reactor critical and power < 15%
- 2 or more dropped or misaligned rods with reactor critical and power >= 15%
- More than 1 uncoupled control rod
- Unanticipated or anomalous reactor behavior
4
Q
AOP-5 immediate actions
A
Trip the reactor if you meet reactor trip criteria