AOP-12 "Loss of EY-10" Flashcards
1
Q
AOP-12 entry conditions
A
- EK-0543 “Preferred AC Bus Number 1 Trouble”
- Channel “A” RPS Trip Ladder Logic lights illuminated
2
Q
AOP-12 automatic actions
A
- P-8A, Motor Driven Aux Feed Pump, control circuitry transfers to EY-30, Preferred AC Bus No 3.
- P-8B, Motor Driven Aux Feed Pump, control circuitry transfers to EY-30, Preferred AC Bus No 3.
- Main Feedwater control for E-50A, “A” S/G, transfers to EY-30, Preferred AC Bus No 3.
3
Q
AOP-12 reactor trip criteria
A
CV-0711, Feed Pump P-1A Recirculation Valve, fails open with reactor power > 80%
4
Q
AOP-12 immediate actions
A