AOP-22 "PZR Level Control Malfunctions" Flashcards
1
Q
AOP-22 entry conditions
A
- EK-0735 “Charging Low Flow”
- EK-0761 “Pressurizer Level HI-LO”
- EK-0763 “Pressurizer Level Channel “A” LO-LO”
- EK-0764 “Pressurizer Level Channel “B” LO-LO”
- EK-0769 “Pressurizer High Level”
- Loss of level control program output signal causing a deviation from the calculated level control setpoint
2
Q
AOP-22 automatic actions
A
- PZR High Level - max letdown, min charging, and PZR Backup Heaters energize (in auto position only)
- PZR Low Level - min letdown, max charging
- PZR Low-Low Level - all PZR Heaters trip, CV-2003, Letdown Orifice Stop Valve, closes
3
Q
AOP-22 reactor trip criteria
A
PZR Level < 30%
4
Q
AOP-22 immediate actions
A
NONE