AOP-26 "Loss of SFP Cooling" Flashcards

1
Q

AOP-26 entry conditions

A
  • EK-1307 “Fuel Pool Clg Pumps P-51A and/or P-51B Trip” AND P-51A or P-51B aligned to spent fuel pool cooling
  • EK-1309 “Spent Fuel Pool HI/LO Level” (LO level @ 646’)
  • Spent Fuel Pool level lowering as indicated on LI-2141, Channel A SFP Level, or LI-2142, Channel B SFP Level
  • TIA_0925_D, “PPC Urgent Alarm, SFP High Temperature” (140 F)
  • TIA_0926_D, “PPC Urgent Alarm, SFP North Tilt Pit High Temperature” (140 F)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

AOP-26 automatic actions

A

NONE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

AOP-26 reactor trip criteria

A

NONE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

AOP-26 immediate actions

A
  • Place irradiated fuel bundles that are in hoist boxes in 1 of the following locations:
    1. bundle’s previous location
    2. bundle’s future location
    3. tilt machine, then tilt horizontal
    4. reactor engineering specified location
  • Lower SFP Elevator to lower limit
  • Move irradiated fuel bundles in Ultrasonic Test Rig or Ultrasonic Fuel Cleaning Rig to their fuel storage rack location
How well did you know this?
1
Not at all
2
3
4
5
Perfectly