636 Emergency Shutdown (66-EOP-5001) Flashcards

1
Q

CCR - 1.1.1 - NOTIFY Asset Team Shift Supervisor (Shift FLS) that 636 Unit will be Shutdown due to Emergency Conditions

A

CCR - 1.1.2 - ANNOUNCE: “All Maintenance, Contract personnel and other non-essential personnel, clear the 636 Unit and adjacent Units within a 300-foot radius for Emergency Shutdown.”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

OPER - 1.1.3 - ENSURE Non-essential Personnel have cleared the 636 unit and adjacent Units within a 300-foot radius

A

CCR - 1.1.4 - DIVERT feed from 636 Unit in accordance with Standing Orders

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

OPER - 1.1.5 - SHUTDOWN Charge Pumps (636P0001A/B)

A

OPER - 1.1.6 - VERIFY that the 66XV5101 and 66XV5102 Feed Chopper valves are closed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

OPER - 1.1.7 - OPEN the 4” H2 Sweep line

A

CCR - 1.1.8 - OPEN Heater pass Feed Control Valves (66FV0009, 66FV0010, 66FV0011 and 66FV0012).

  • ENSURE 66HS0069A is engaged
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

CCR - 1.1.9 - BLOW DOWN each pass on 636F0001, Reactor Feed Heater, by performing the following:

A - PLACE 3 of the 4 Heater Pass Feed Control Valves (66FV0009, 66FV0010, 66FV0011, and 66FV0012) in manual to approximately 10%

A

B - BLOW DOWN the pass for a minimum of 15 minutes with Hydrogen flow from running compressor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

C - OPEN 1 of the 3 isolated pass control valves and close the previously open pass control valve to approximately 10% at end of blow-down time period

A

D - REPEAT for other 3 passes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

E - ONCE the sweep is complete,
OPEN all 4 of the heater pass control valves for an additional hour

A

OPER - 1.1.10 - CLOSE the 4” H2 Sweep line

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

CCR - 1.1.11 - CLOSE all 4 of the heater pass control valves

A

OPER - 1.1.12 - ENSURE that the 634C00002 Compressor seals are in 634 service

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

OPER - 1.1.13 - ENSURE that 64PC00039, Hydrogen to 735 is aligned to send 634 Hydrogen to 735 and isolated form the 636 Hydrogen.

A

CCR - 1.1.14 - PLACE 66FV0072 H2 to 634 controller in Manual and CLOSE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

OPER - 1.1.15 - UNLOAD either 636C000022A or B Compressor and shut it down

A

CCR - 1.1.16 - MAINTAIN purge with one Makeup compressor and the Recycle Gas Compressor (636C0001), until remaining Feed is removed from unit, as indicated by Hot Seperator Level Indicator (66LI0003A) indications are Stable

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

CCR - 1.1.17 - PLACE Stripping Steam Flow Controller for the Stripper (66FC0035) and Fractionator (66FC0051) in Manual and Close

A

OPER - 1.1.147 - SHUTDOWN Stripper Bottoms Pumps (636P0006A/B) when the discharge pressure on Stripper Bottoms, Pump is decreasing, as indicated by local indicators (66PI0119/20)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

CCR - 1.1.19 - REDUCE temperature setpoint on Charge heater Outlet Temperature Controller (66TC0016), to 300 degrees F at a rate of 150 degrees F per hour, or as directed by Ref Tech

A

CCR - 1.1.20 - PLACE the following Controllers in manual and Close:

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q
  • Stripper Level Controller (66LC0014)
A
  • Fractionator Charge Heater Tube No. 1 Flow Controller (66FC0049A)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q
  • Fractionator Charge Heater Tube No. 2 Flow Controller (66FC004B)
A
  • Fractionator Charge Heater Tube No. 3 Flow Controller (66FC0049C)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

CCR - 1.1.21 - PLACE Fractionator Charge Heater Tube No. 4 Flow Controller (66FC0049D), in Manual and OPEN

A

OPER - 1.1.22 - CLOSE the 636P0006A/B, Stripper Bottoms Pumps discharge valves

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

OPER - 1.1.23 - OPEN 4” valve on Medium Pressure Steam line to Stripper Bottoms Pump (636P0006A/B), Discharge line to purge through Stripper Feed Bottom Exchangers (636E0011A-F) and Product Fractionator Charger Heater (636F0002)

A

CCR - 1.1.24 - OPEN Fractionator Charge heater Tube No. 3 Flow Controller (66F0049C)

17
Q

CCR - 1.1.25 - CLOSE Fractionator Charge heater Tube No. 4 Flow Controller (66FC0049D)

A

CCR/OPER - 1.1.26 - REPEAT Step1.1.24 through Step 1.1.25 for the following Fractionator Charge Heater Tubes:

  • No. 2 Flow Controller (66FC0049B)
  • No. 1 Flow Controller (66FC0049A)
18
Q

OPER - 1.1.27 - CLOSE 4” valve on Medium Pressure steam line to Stripper Bottoms Pump Discharge line

A

CCR - 1.1.28 - OPEN the following Tube Flow Controllers on Fractionator Charge Heater

  • No. 2 (66FC0049B)
  • No. 3 (66FC0049C)
  • No. 4 (66FC0049D)
19
Q

CCR/OPER - 1.1.29 - REMOVE the Fractionator from service per HDSC-SOP-2012, Fractionator Operation/Maintenance Preparation procedure

A

OPER - 1.1.30 - SHUTDOWN compressors when Outlet temperature on Reactor (636R0001), is equal to or less than300 degrees F, as indicated by Reactor Outlet Temperature Indicator (66TI0088)

20
Q

1.2 Complete Supplemental Actions

A