633 Reactor SPS Trip (63-EOP-5041) Flashcards
CCR - 1.1.1 - NOTIFY appropriate parties that the 633 Unit will be Shutdown under emergency conditions
OPER - 1.1.2 - ENSURE non-essential personnel have cleared 633 Unit and adjacent Unites within 300’ radius.
CCR/OPER - 1.1.3 - NOTIFY Oil Movements Pumper Operator that 633 HDS feed will be bypassed to product.
OPER - 1.1.4 - OPEN both 10” chain valves in alley SW of Plot Edge on Jump Over Line from feed to product.
OPER - 1.1.5 - CLOSE 10” battery limits isolation valve on Feed line, located below circulation line.
CCR - 1.1.6 - DIVERT Coker LGO to 635 or Tankage as needed
CCR/OPER - 1.1.7 - UNLOAD the Recycle end of the 633C0001A/B or Sparing 635 compressor and shutdown.
1.2 - Complete Supplemental Actions