TOOLS 7 - COCKLOFT NOZZLE Flashcards
TOOLS 7 - COCKLOFT NOZZLE
WHAT IS THE LENGTH OF THE COCKLOFT NOZZLE?
6’3”
TOOLS 7 - COCKLOFT NOZZLE
TRUE/FALSE
THE TWO 1/2” OST’S OF THE COCKLOFT NOZZLE ARE REMOVABLE.
FALSE
THE TWO 1/2” TIPS OF THE COCKLOFT NOZZLE’S OST ARE NOT TO BE REMOVED.
TOOLS 7 - COCKLOFT NOZZLE
WHAT IS THE REACH OF THE STREAM OF THE COCKLOFT NOZZLE?
EXCESS OF 60 FT
TOOLS 7 - COCKLOFT NOZZLE
WHAT IS THE DISCHARGE RATE OF THE COCKLOFT NOZZLE?
APPRX. 125 GPM
TOOLS 7 - COCKLOFT NOZZLE
WHAT SIZE LINE IS THE COCKLOFT NOZZLE SUPPLIED WITH?
COCKLOFT NOZZLE SUPPLIED WITH 1 3/4” HANDLINE
++OPERATES WITH THE SAME PRESSURE NORMALLY SUPPLIED TO A 1 3/4” HANDLINE++
TOOLS 7 - COCKLOFT NOZZLE
TRUE/FALSE
THE COCKLOFT NOZZLE CAN BE A PRIMARY ATTACK LINE.
FALSE
++THE COCKLOFT NOZZLE SHOULD NEVER BE THE PRIMARY ATTACK LINE AND IS ONLY TO BE USED WHEN SUPPORTED AND PROTECTED BY AN ADDITIONAL CONVENTIONAL HANDLINE++
TOOLS 7 - COCKLOFT NOZZLE
WHICH UNITS CARRY THE COCKLOFT NOZZLE?
SQUADS AND DIVISIONS
TOOLS 7 - COCKLOFT NOZZLE
HOW DO YOU CONNECT THE COCKLOFT NOZZLE TO 1 3/4” HOSE?
COCKLOFT NOZZLE CAN BE ATTACHED TO ANY CONTROLLING NOZZLE BY SIMPLY REMOVING THE MST OF THE CONTROLLING NOZZLE AND THEN CONNECTING THE 1 1/2” FEMALE COUPLING OF THE COCKLOFT NOZZLE TO THE SHUT-OFF
TOOLS 7 - COCKLOFT NOZZLE
WHAT SHOULD BE CONSIDERED PRIOR TO USING THE COCKLOFT NOZZLE AT NFP MULTIPLE DWELLING COCKLOFT FIRES?
CUTTING A VENT HOLE OVER THE MAIN BODY OF FIRE
TOOLS 7 - COCKLOFT NOZZLE
WHAT IS THE PREFERRED LOCATION FOR OPERATION OF THE COCKLOFT NOZZLE AT A NFP MD?
IMMEDIATELY INSIDE THE APARTMENT DOOR
TOOLS 7 - COCKLOFT NOZZLE
WHAT SIZE HOLDE SHOULD BE CUT IN THE CEILING IN ORDER FOR THE COCKLOFT NOZZLE TO FIT?
3’X3’
3 FOOT BY 3 FOOT
TOOLS 7 - COCKLOFT NOZZLE
WHAT IS THE MINIMUM AMOUNT OF SPACE NEEDED BETWEEN THE TOP OF THE CEILING JOISTS AND THE BOTTOM OF THE ROOF JOISTS TO ENABLE COCKLOFT NOZZLE OPERATIONS?
4 INCHES
TOOLS 7 - COCKLOFT NOZZLE
YOUR MEN ARE OPERATING THE COCKLOFT NOZZLE, THE NOZZLE IS POSITIONED JUST INSIDE THE APT DOOR, THE HOLE IS 3X3 AND YOU HAVE A PROTECTION LINE BEHIND YOU. YOUR NOZZLE MAN IS ROTATING THE COCKLOFT NOZZLE IN A CONTINUOUS COUNTER-CLOCKWISE DIRECTION. IS YOUR NOZZLEMAN OPERATING CORRECTLY?
NO
++DO NOT ROTATE THE COCKLOFT NOZZLE IN A CONTINUOUS COUTER CLOCKWISE DIRECTION, THIS ACTION MAY CAUSE THE NOZZLE TO BECOME UNSCREWED FROM TEH SHUT-OFF++
TOOLS 7 - COCKLOFT NOZZLE
YOU SHOULD INSTRUCT YOUR NOZZLEMAN TO OPERATE THE COCKLOFT NOZZLE BY ALTERNATING THE DIRECTION OF THE STREAM BY ROTATING THE NOZZLE _____ DEGREES AND RETURNING THE NOZZLE TO ITS ORIGINAL POSITION TO PROVIDE MAXIMUM COVERAGE.
90 DEGREES
TOOLS 7 - COCKLOFT NOZZLE
YOU ARE THE TRUCK OFFICER OF LADDER 136, E287 HAS JUST EXTINGUISHED A COCKLOFT FIRE AT A NFPMD. YOU INSTRUCT YOUR MEN THAT NO CEILINGS NEED TO BE PULLED FOR FINAL EXTINGUISHMENT AND WASHDOWN. YOU INFORM THE CHIEF THAT ALL FIRE HAS BEEN KNOCKED DOWN AND THAT THE FIRE IS OUT. DID YOU OPERATE CORRECTLY?
NO
++THE USE OF THE COCKLOFT NOZZLE DOES NOT ELIMINATE THE NEED OF PULLING CEILINGS FOR FINAL EXTINGUISHMENT AND WASHDOWN++