EVOLUTIONS 9 - SUPPLY A LINE FROM STANDPIPE Flashcards
EVOLUTIONS 9 - SUPPLY WATER TO A STANDPIPE SYSTEM THROUGH A SIAMESE AND OPERATE A HOSE LINE FROM A FLOOR OUTLET
What lengths does the back-up man connect during standpipe operations?
Back up man connects hose butts between 2nd and 3rd lengths
EVOLUTIONS 9 - SUPPLY WATER TO A STANDPIPE SYSTEM THROUGH A SIAMESE AND OPERATE A HOSE LINE FROM A FLOOR OUTLET
What lengths does the nozzle connect during standpipe operations?
Nozzle connects hose butts between lead length and 2nd length
EVOLUTIONS 9 - SUPPLY WATER TO A STANDPIPE SYSTEM THROUGH A SIAMESE AND OPERATE A HOSE LINE FROM A FLOOR OUTLET
What lengths does the control man connect during standpipe operations?
Control man connects inline pressure gauge and hose line to the standpipe outlet.
EVOLUTIONS 9 - SUPPLY WATER TO A STANDPIPE SYSTEM THROUGH A SIAMESE AND OPERATE A HOSE LINE FROM A FLOOR OUTLET
If the doorman is present what are his duties?
- Connects hose butts between 3rd and 4th lengths (if needed).
- Assists Control firefighter in hooking up to standpipe.
- Assists Nozzle and Backup firefighters.
EVOLUTIONS 9 - SUPPLY WATER TO A STANDPIPE SYSTEM THROUGH A SIAMESE AND OPERATE A HOSE LINE FROM A FLOOR OUTLET
All hoselines stretched from standpipe shall be _______ hose with controlling nozzle and _____ Main Stream Tip. All handlines should be stretched from ______________.
All hoselines stretched from standpipe shall be 2½” hose with controlling nozzle and 1⅛” Main Stream Tip. All handlines should be stretched from the floor below.
EVOLUTIONS 9 - SUPPLY WATER TO A STANDPIPE SYSTEM THROUGH A SIAMESE AND OPERATE A HOSE LINE FROM A FLOOR OUTLET
Variations from stretching initial hoselines from standpipe outlets on a floor below the fire due to building configurations shall be approved by _________________ and placed in the __________ program.
Variations from stretching initial hoselines from standpipe outlets on a floor below the fire due to building configurations shall be approved by DIVISION COMMANDER and placed in the CIDS program.
EVOLUTIONS 9 - SUPPLY WATER TO A STANDPIPE SYSTEM THROUGH A SIAMESE AND OPERATE A HOSE LINE FROM A FLOOR OUTLET
TRUE/FALSE
Controlling nozzle must always be carried attached to the folded lead length.
TRUE
EVOLUTIONS 9 - SUPPLY WATER TO A STANDPIPE SYSTEM THROUGH A SIAMESE AND OPERATE A HOSE LINE FROM A FLOOR OUTLET
The color markings for the standpipe system are as follows:
STANDPIPE -
AUTOMATIC SPRINKLER -
NON-AUTOMATIC SPRINKLER -
COMBINATION STANDPIPE/SPRINKLER -
STANDPIPE - RED
AUTOMATIC SPRINKLER - GREEN
NON-AUTOMATIC SPRINKLER - ALUMINUM
COMBINATION STANDPIPE/SPRINKLER - YELLOW
EVOLUTIONS 9 - SUPPLY WATER TO A STANDPIPE SYSTEM THROUGH A SIAMESE AND OPERATE A HOSE LINE FROM A FLOOR OUTLET
If building is equipped with both standpipe and sprinkler systems and standpipe is to be used, the engine company first to arrive must connect first line to ____________ and second line to ____________.
If building is equipped with both standpipe and sprinkler systems and standpipe is to be used, the engine company first to arrive must connect first line to STANDPIPE SIAMESE and second line to SPRINKLER SIAMESE.