EVOLUTIONS 9 - SUPPLY A LINE FROM STANDPIPE Flashcards

0
Q

EVOLUTIONS 9 - SUPPLY WATER TO A STANDPIPE SYSTEM THROUGH A SIAMESE AND OPERATE A HOSE LINE FROM A FLOOR OUTLET

What lengths does the back-up man connect during standpipe operations?

A

Back up man connects hose butts between 2nd and 3rd lengths

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

EVOLUTIONS 9 - SUPPLY WATER TO A STANDPIPE SYSTEM THROUGH A SIAMESE AND OPERATE A HOSE LINE FROM A FLOOR OUTLET

What lengths does the nozzle connect during standpipe operations?

A

Nozzle connects hose butts between lead length and 2nd length

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

EVOLUTIONS 9 - SUPPLY WATER TO A STANDPIPE SYSTEM THROUGH A SIAMESE AND OPERATE A HOSE LINE FROM A FLOOR OUTLET

What lengths does the control man connect during standpipe operations?

A

Control man connects inline pressure gauge and hose line to the standpipe outlet.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

EVOLUTIONS 9 - SUPPLY WATER TO A STANDPIPE SYSTEM THROUGH A SIAMESE AND OPERATE A HOSE LINE FROM A FLOOR OUTLET

If the doorman is present what are his duties?

A
  • Connects hose butts between 3rd and 4th lengths (if needed).
  • Assists Control firefighter in hooking up to standpipe.
  • Assists Nozzle and Backup firefighters.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

EVOLUTIONS 9 - SUPPLY WATER TO A STANDPIPE SYSTEM THROUGH A SIAMESE AND OPERATE A HOSE LINE FROM A FLOOR OUTLET

All hoselines stretched from standpipe shall be _______ hose with controlling nozzle and _____ Main Stream Tip. All handlines should be stretched from ______________.

A

All hoselines stretched from standpipe shall be 2½” hose with controlling nozzle and 1⅛” Main Stream Tip. All handlines should be stretched from the floor below.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

EVOLUTIONS 9 - SUPPLY WATER TO A STANDPIPE SYSTEM THROUGH A SIAMESE AND OPERATE A HOSE LINE FROM A FLOOR OUTLET

Variations from stretching initial hoselines from standpipe outlets on a floor below the fire due to building configurations shall be approved by _________________ and placed in the __________ program.

A

Variations from stretching initial hoselines from standpipe outlets on a floor below the fire due to building configurations shall be approved by DIVISION COMMANDER and placed in the CIDS program.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

EVOLUTIONS 9 - SUPPLY WATER TO A STANDPIPE SYSTEM THROUGH A SIAMESE AND OPERATE A HOSE LINE FROM A FLOOR OUTLET

TRUE/FALSE

Controlling nozzle must always be carried attached to the folded lead length.

A

TRUE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

EVOLUTIONS 9 - SUPPLY WATER TO A STANDPIPE SYSTEM THROUGH A SIAMESE AND OPERATE A HOSE LINE FROM A FLOOR OUTLET

The color markings for the standpipe system are as follows:

STANDPIPE -
AUTOMATIC SPRINKLER -
NON-AUTOMATIC SPRINKLER -
COMBINATION STANDPIPE/SPRINKLER -

A

STANDPIPE - RED
AUTOMATIC SPRINKLER - GREEN
NON-AUTOMATIC SPRINKLER - ALUMINUM
COMBINATION STANDPIPE/SPRINKLER - YELLOW

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

EVOLUTIONS 9 - SUPPLY WATER TO A STANDPIPE SYSTEM THROUGH A SIAMESE AND OPERATE A HOSE LINE FROM A FLOOR OUTLET

If building is equipped with both standpipe and sprinkler systems and standpipe is to be used, the engine company first to arrive must connect first line to ____________ and second line to ____________.

A

If building is equipped with both standpipe and sprinkler systems and standpipe is to be used, the engine company first to arrive must connect first line to STANDPIPE SIAMESE and second line to SPRINKLER SIAMESE.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly