WHEN REMOVING HOSE FROM THE APPARATUS One member mounts rear step of apparatus, places arm through first 3 folds of hose, gives a strong pull, steps down and walks backward, dragging hose. Firefighter lays hose on ground about _____ feet from apparatus and slightly to side in direction of stretch.
15 FT
4.1 One member mounts rear step of apparatus, places arm through first 3 folds of hose, gives a strong pull, steps down and walks backward, dragging hose. Firefighter lays hose on ground about 15 feet from apparatus and slightly to side in direction of stretch.
WHEN PERFORMING THE BACKSTRETCH, WHICH MEMBER OF THE ENGINE WILL RIDE THE BACK STEP AS THE PUMPER PROCEEDS TO HYDRANT?
•CONTROL FF
3.2 Pumper proceeds to hydrant playing out hose on way. One member (control firefighter) rides rear step, standing clear of moving hose.
DEFINE BACKSTRETCH:
•ENGINE COMPANY REACHES THE FIRE BEFORE THE HYDRANT
DESCRIBE INLINE PUMPING:
PUMPER REACHES THE HYDRANT BEGORE THE FIRE
IF PERFORMING INLINE PUMPING IN A 4 FF ENGINE WHICH FF IS THE HYDRANT FF & WHICH IS THE HOSE FF?
•CONTROL FF [CONTROL FF IS ALWAYS DESIGNATED THE HYDRANT FF]
INLINE PUMPING
4 FF ENGINE:
HYDRANT FF - CONTROL
HOSE FF - BACK-UP
5 FF ENGINE:
HYDRANT FF - CONTROL
HOSE FF - DOOR
IF PERFORMING INLINE PUMPING IN A 4 FF ENGINE, WHICH FF IS DESIGNATED THE HOSE FF?
•BACK UP
INLINE PUMPING
4 FF ENGINE:
HYDRANT FF - CONTROL
HOSE FF - BACK-UP
5 FF ENGINE:
HYDRANT FF - CONTROL
HOSE FF - DOOR
IF PERFORMING INLINE PUMPING IN A 5 FF ENGINE WHICH FF IS DESIGNATED THE HOSE FF?
•DOOR
INLINE PUMPING
4 FF ENGINE:
HYDRANT FF - CONTROL
HOSE FF - BACK-UP
5 FF ENGINE:
HYDRANT FF - CONTROL
HOSE FF - DOOR
E287 (4 FF’S) IS DRILLING ON INLINE PUMPING. WHICH FF WILL TEST THE HYDRANT?
•CONTROL FF [HYDRANT FF IS ALWAYS CONTROL]
3.1 Pumper stops so that the rear step is opposite the hydrant. The Hydrant FF equipped with a hydrant wrench and a 2½” gate, tests the hydrant.
4 FF Engine Co.
Hydrant FF - Control FF
Hose FF - Back-up FF
5 FF Engine Co.
Hydrant FF - Control FF
Hose FF - Door FF
E324 IS RIDING WITH 5 FF’S ON A SNOWNY DECEMBER NIGHT. IF E324 AT ANY OPERATION PERFORMED INLINE PUMPING, WHICH FF WOULD CHECK THE HYDRANT?
•CONTROL FF
3.1 Pumper stops so that the rear step is opposite the hydrant. The Hydrant FF equipped with a hydrant wrench and a 2½” gate, tests the hydrant.
4 FF Engine Co.
Hydrant FF - Control FF
Hose FF - Back-up FF
5 FF Engine Co.
Hydrant FF - Control FF
Hose FF - Door FF
DURING INLINE PUMPNG PROCEDURES AFTER THE HYDRANT IS DEEMED SERVICEABLE THE HOSE FF WILL PULL SUFFICIENT AMOUNT OF 3 1/2” HOSE FROM THE RIG & TAKE TURNS AROUND THE HYDRANT. WHICH FF MOUNTS THE PUMPERS BACKSTEP & PREPARES TO SIGNAL THE ECC USING THE BUZZERS?
•HOSE FF [4 FF-BACKUP/5 FF-DOOR]
4 FF Engine Co.
Hydrant FF - Control FF
Hose FF - Back-up FF
5 FF Engine Co.
Hydrant FF - Control FF
Hose FF - Door FF
WHEN THE HYDRANT FF KEYS THE HYDRANT, HOW MUCH OF A TAIL IS LEFT AFTER THE HYDRANT?
2 FT
TRUE/FALSE
DURING INLINE PUMPING HOOKING UP INLINE PUMPING OPERATIONS SHALL BE GIVEN PRIORITY OVER SUPPLYING BOOSTER WATER, NO MATTER IF THE OFFICER HAS CALLED FOR BOOSTER.
FALSE
Supplying booster water upon Officer’s orders shall be given priority over hooking up the in-line supply line.
IN A 4 FF ENGINE - DURING INLINE PUMPING OPS WHICH FF INITIALLY CONTROLS THE STRETCH UNTIL RELIEVED BY THE HYDRANT FF?
•ECC
3.6 Depending on staffing, the initial handline stretch will be controlled by either the Door FF (5 FF Engine) or the ECC (4 FF Engine), until relieved by the Control FF (Hydrant Firefighter).
IN A 5 FF ENGINE - DURING INLINE PUMPING OPS WHICH FF INITIALLY CONTROLS THE STRETCH UNTIL RELIEVED BY THE HYDRANT FF?
•DOOR
3.6 Depending on staffing, the initial handline stretch will be controlled by either the Door FF (5 FF Engine) or the ECC (4 FF Engine), until relieved by the Control FF (Hydrant Firefighter).
WHAT SIZE MAIN MUST A HYDRANT BE ON IF IT WERE TO BE USED FOR INLINE PUMPING?
•6 INCH MAIN OR LARGER
Hydrant selected for ILP must be on a 6” or larger main. During Water Alert, ILP shall not be used unless absolutely necessary.