1MY ACRONYMS Flashcards
5 MAIN FUNCTIONS OF ICS
C-FLOP
C-FLOP
COMMAND FINANCE/ADMINISTRATION LOGISTICS OPERATIONS PLANNING
UPON ARRIVING THE LOBBY CONTROL UNIT VERIFIES THE LOCATION OF?
FORWARD-FORWARD-SAFE-FIRE
FORWARD-FORWARD-SAFE-FIRE
FORWARD STAGING AREA
FORWARD TRIAGE AREA
SAE POST (SEARCH AND EVACUATION POST)
FIRE FLOOR
STANDPIPE KIT
IECAPSONG
IECAPSONG
I - INCREASER 1 1/2 X 2 1/2" CONNECTED TO E - EXTRA 2 1/2" NOZZLE C - CHOCKS A - ADAPTORS P - PIPE WRENCH (MIN. 18") S - SPANNERS O - OUTLET VALVE HAND CONTROL WHEEL N - NOZZLE 2 1/2" 1 1/8" MST G - INLINE PRESSURE GUAGE 2 1/2 X 2 1/2"
THE LOBBY CONTROL UNIT WILL MAINTAIN THIS EQUIPMENT IN EACH ELEVATOR :
CHEESES
C - CLIPBOARD H - H.T. E - ELEVATOR KEYS E - ELEVATOR CONTROL SHEET S - SEARCH ROPE E - ENTRY TOOLS - FORCIBLE ENTRY TOOLS S - SPARE CYLINDER
REASONS WHY A COMPANY OFFICER WOULD ORDER A 2 1/2” HOSE STRETCHED:
DALLAS
D - DEFENSIVE POSITION A - ADVANCED FIRE ON ARRIVAL L - LARGE VOLUME OF WATER REQUIRED L - LARGE BODY OF FIRE IN AN UNCOMPARTMENTED AREA A - AREA UNDETERMINED S - STANDPIPE
High rise roof team tool assignment:
B BRASH 6 60
B BRASH 6 60
B - BAG FOR TOOLS B - BOLT CUTTERS R - RABBIT TOOL A - 2 AXES S - 2 SEARCH ROPES H - 2 HALLIGANS
6 60 MIN CYLINDERS
Dangers of chemical suicide to responders:
FIBS
FIBS
F - FLAMMABILITY
I - INHALATION PRIMARY
B - BLOOD BORNE
S - SKIN ABSORPTION
Steps to clear ice from an aerial ladder:
Rudy Loves Tommy Boy
DOUBLE CHECK
Rudy Loves Tommy Boy
R - Rungs
L - Ladder locks
T - Trusses
B - BEAMS
Reports company officers must prepare and sign:
MUDIFAC
MUDIFAC
M - Meritorious Acts U - Unusual Occurence D - Death I - Injuries F - Fire A - Accidents C - Charges
Priority order of Gas shutoff:
“All Men Honestly Expect Casual Sex”
“All Men Honestly Expect Casual Sex”
A -- APPLIANCE M -- METER H -- HEAD OF SERVICE VALVE E -- EXTERIOR GAS RISER C -- CURB VALVE S -- STREET SHUTOFF
COMMUNICATIONS BETWEEN ICP AND PARTS OF HIGH RISE BUILDING
WAMEE-P
WAMEE-P
W -- WARDENS A -- AIR HANDLING M -- MECHANICAL CONTROL CENTER E -- ELEVATORS E -- ELEVATOR MACHINE ROOM P -- PUMP ROOM
COMMUNICATIONS BETWEEN ICP AND PARTS OF HIGH RISE BUILDING
WAMEE-P
WAMEE-P
W -- WARDENS A -- AIR HANDLING ROOM M -- MECHANICAL CONTROL CENTER E -- ELEVATORS E -- ELEVATOR MACHINE ROOM P -- FIRE PUMP ROOM
Priority order of Gas shutoff:
“All Men Honestly Expect Casual Sex”
“All Men Honestly Expect Casual Sex”
A -- APPLIANCE M -- METER H -- HEAD OF SERVICE VALVE E -- EXTERIOR GAS RISER C -- CURB VALVE S -- STREET SHUTOFF
HIERARCHY OF COLLAPSE ACCORDING TO DUNN (LEAST TO GREATEST)
DAN BOCIAN GETS CHARLIE BEER
DAN BOCIAN GETS CHARLIE BEER
D - DECK B - BEAM G - GIRDER C - COLUMN B - BEARING WALL
ENGINE COMPANY PRIORITY ORDER OF EXTINGUISHMENT AT A COLLAPSE
BOB DALY EATS COCK
BOB DALY EATS COCK
B - BUILDING
D - DEBRIS
E - EXPOSURES
C - CARS
SINGLE UNIT RESPONSE
BROIL FOSS
BROIL FOSS
B -- BRUSH R -- RUBBISH O -- OIL BURNER I -- INCINERATOR L -- LEAK WATER
F – FOOD ON STOVE
O – ODOR OF SMOKE
S – SPRINKLER
S – STEAM
DEPARTMENT OF TRANSPORTATION CLASSIFICATION OF CHEMICAL ACCORDING TO MAJOR HAZARDOUS CHARACTERISTICS
EVERY GOOD LT. S.O.P. REQUIRES COORDINATING MEMBERS
EVERY GOOD LT. S.O.P. REQUIRES COORDINATING MEMBERS
1 -- E -- EXPLOSIVES 2 -- G -- COMPRESSED GASES 3 -- L -- FLAMMABLE LIQUIDS 4 -- S -- FLAMMABLE SOLIDS 5 -- O -- OXIDIZERS 6 -- P -- POISONS 7 -- R -- RADIOACTIVE MATERIAL 8 -- C -- CORROSIVES 9 -- M -- MISCELLANEOUS
PERCENTAGE LOSS OF WATER IF BY-PASS VALVE IS LEFT ON IN A HIGH RISE OFFICE BUILDING WHEN OPERATING MANUAL FIRE PUMPS:
“RULE OF 15”
“RULE OF 15”
25% FOR AN 8” RISER (2+5+8=15)
45% FOR A 6” RISER (4+5+6=15)
THE FOUR STEP PROCEDURE FOR STARTING THE PUMPS AT A HIGH RISE OFFICER BUILDING:
“KC START THE LEVER”
“KC START THE LEVER”
K - KNIFE (CLOSE KNIFE SWITCH TO ON POSITION)
C - CIRCUIT (CLOSE CIRCUIT BREAKER)
START - PUSH START BUTTON
LEVER - MOVE LEVER
HVAC IN NON-CIRCULATING MODE FOR HIGH RISE OFFICE
OPEN-CLOSE MIXING-OPEN
OPEN ALL OUTSIDE SUPPLY DAMPERS
CLOSE ALL MIXING DAMPERS
OPEN EXHAUST DAMPERS
++YOU ARE OPENING OUTISDE & CLOSING INSIDE++
Reports company officers must prepare and sign:
MUDIFAC
MUDIFAC
M - Meritorious Acts U - Unusual Occurence D - Death I - Injuries F - Fire A - Accidents C - Charges
Reports company officers must prepare and sign:
MUDIFAC
MUDIFAC
M - Meritorious Acts U - Unusual Occurence D - Death I - Injuries F - Fire A - Accidents C - Charges
OFFICER 1ST TO FIRE AREA MUST TRANSMIT TO IC?
LODANCE
LODANCE
L - LOCATION OF FIRE O - OCUPPANTS LOCATED/MISSING D - DIFFICULTY GAINING ENTRANCE OR ADVANCING LINE A - ACCESS TO FIRE ARE N - NUMBER OF APTS C - CONDITIONS OF FIRE E - EXTENSION
PREFERENTIAL ORDER OF BREACHING A WALL IN AN OLT WITH TOOLS
HA-HA
HA-HA
HA - HALIGAN
H - HOOK
A - AXE
FDNY CORE COMPETENCIES:
FEM SLAM
FEMSLAM
F – FIRE SUPPRESSION
E – EVACUATION OF STRUCTURE
M – MEDICAL CARE
S – SEARCH AND RESCUE
L – LIFE SAFETY AT CBRN/HAZMAT
A – ARSON INVESTIGATION
M – MASS DECON
FDNY SINGLE COMMAND EVENTS
BEST CAFE
B – BOAT IN DISTRESS
E – ELEVATOR INCIDENT/EMERGENCY
S – STRUCTURAL COLLAPSE
T – DOWNED TREE
C – CONFINED SPACE RESCUE
A – AUTO EXTRICATION
F – FIRE
E – ENTRAPMENT/IMPALEMENT
++HAZMAT INCIDENTS WITH NO TERRORISM SUSPECTED, AS DETERMINED BY NYPD, UNIFIED COMMAND++
WHEN DEALING WITH MANAGEMENT ISSUES, PRIORITY ORDER OF ISSUES TO DEAL WITH:
SUOR
S - SUPERIORS
U - UPSET
O - OUTSIDES BEFORE INSIDERS
R - ROUTINE
ORDER OF PUMP PRESSURE IN HIGH RISE BUILDINGS:
FLOORS PRESSURE
1 - 10 —– 150 PSI
31 - 40 —– 300 PSI - HIGH PRESSURE PUMPING BEGINS
81 - 90 —– 550 PSI - 3RD STAGE PUMPING RECOMMENDED
101 - UP —– 650 PSI - 3RD STAGE REQUIRED
10-35 UNWARRANTED/UNECESSARY ALARM
TOM CORRAR HATES OLIVER
10-35 NO CODE – UNWARRANTED ALARM
10-35 SUBCODES ARE UNNECESSARY ALARMS (TCHO) 10-35 CODE 1 - TESTING 10-35 CODE 2 - CONSTRUCTION 10-35 CODE 3 - HOUSEHOLD 10-35 CODE 4 - OTHER
++CODE 4 GETS NYFIRS REPORT++
10-34 SPRINKLER EMERGENCY
DUH
10-34 SPRINKLER EMERGENCY
“DUH”
D - 10-34 CODE 1 DEFECTIVE
U - 10-34 CODE 2 UNWARRANTED
H - 10-34 CODE 3 HEAT NOT ASSOCIATED WITH FIRE
PROPER WAY TO DON BUNKER GEAR:
PUERTO RICANS HATE COCKAROACHES
PUERTO RICANS HATE COCKAROACHES
P – PANTS/BOOTS
R – RADIO
H – HOOD
C – COAT
10-36 CAR ACCIDENT
NO WAIT
10-36 CAR ACCIDENT
“NO WAIT”
10-36 NO CODE - ANY OTHER
10-36 CODE 1 - WASHDOWN
10-36 CODE 2 - ACCIDENT W/O INJURIES OR WASHDOWN
10-36 CODE 3 - ACCIDENT W/INJURIES
10-36 CODE 4 - TOOL: ACCIDENT REQUIRING EXTRICATION
AT A BUCKEYE PIPELINE THAT IS LEAKING YOU TRANSMIT?
LATE
BUCKEYE PIPELINE LEAK
LATE
L – LOCATION
A – AMOUNT
T – TOPOGRAPHY
E – EXPOSURES
IF CONTACT CANNOT BE MADE WITH YOUR COMPANY OFFICER, PRIORITY ORDER OF CONTACT?
CIA
PRIORITY ORDER OF CONTACT
CIA
C – CHAUEFFER
I – INCIDENT COMMANDER
A – ANY OTHER H.T. EQUIPPED MEMBER
INFORMATION ON ENGINE COMPANY BLACKBOARD
CHESS
CHESS
C -- COMPANIES OOS H -- HYDRANTS OOS E -- EQUIPMENT CHANGES ON RIG S -- STANDPIPES OOS S -- STREET CLOSINGS