Tools 17 Mulitversal Flashcards
What must be done to remove the mulitversal from its base
- Lift locking plunger retaining latch
- Pull locking plunger outward
- Lift mulitversal from base
How many members shall be used to remove the mulitversal nozzle from apparatus and lower to ground
Two members
How many members are needed to transport Multiversal
One member
When placing the portable ground base into operation how do you know that it’s placed correctly on the floor
Front leg (leg with safety chain ) pointed towards point of operation
The two inlets of the Siamese face directly to the rear in line with front leg
Locking plunger directly in line with front leg
When placing the T handle on the notched stud protruding from the tapered post on the underside of the mount , we know it’s placed correctly on the stud by ensuring
The T handle is up
Max pressure the mulitversal shall be subject to
200 psi
The Multiversal shall not operate above ______gpm using straight steam or fog
800 GPM
In order to avoid going over the 800 GPM with straight stream tips the pressure shall not exceed
1 “1/4 tip no more than 100 psi
1 “1/2 tip no more than 70 psi
2 “ tip no more than 50 psi
After use the portable ground base should be inspected . If the flats on end the spikes exceed this
1/16” in diameter
Mulitversal oos
Notify repairs and transportation unit
Routine Maintenance shall be conducted
Quarterly
In portable position the horizontal rotation is limited too
90 degrees in each direction from straight ahead point
When Multiversal is on truck mount the vertical range of nozzle is
15 degrees below the horizontal to 90 degrees above the horizontal
If necessary to operate the mulitversal below 35 degrees than
- Release safety stop by pulling up the release pin before reaching 35 degrees
When using the portable mount must the safety chain be used
No should be used if it reach substantial object
MUST BE SECURED WITH ROPES TO SUBSTANTIAL OBJECT