Emergencies 4 Supspended Scaffold Flashcards
When cordoning off area below scaffolding units should ?
Cordon to vehicular and pedestrian traffic
Tape off area
Danger area for civilians and FD members
ALL apparatus kept clear of danger Area and parked In safe location
Enter building from entrance out of danger area if possible
Be weary of hazardous materials
What are the 3 types of scaffold emergencies ?
- Unoccupied swinging scaffold
- Occupied stalled scaffold
- Occupied hanging or off-level scaffold
If arc welding is being performed from scaffolding ensure what
That the unit has a proper secondary ground to avoid electrocution
Procedure for unoccupied suspended scaffold?
Locate window nearest scaffold
Secure scaffold with utility ropes
Inspect exterior of the building for damaged or loose building/scaffold material that may fall
Survey anchoring system on roof :
Parapets hooks and clamps used inspect parapet wall
Check if tie backs are in place and secure
If suspect secure with utility rope
Communicate findings to units below
Members in an emergency ( ie scaffold going to fall)may go out on unoccupied Scaffolding to secure it as long as safety precautions are taken?
No never everything from inside window
Tactics at a occupied stalled suspended scaffolding?
Communicate with stranded workers from nearest window
If on windowless area of building consider lowering HT from above
Ascertain from workers:
1. Workers physical and mental state
2. If workers know cause of stall and If they can correct it
3. If any workers inside building
Check rigging on roof and electrical connections on roof level ( do not restore power w/o permission from units below
4. If in reach of TL or aerial use apparatus to effect removal
5. Window removal as last resort
If the wire rope hoist line is jammed within unit the workers should continue to operate hoist so they can free the jammed rope
No never may severe line
If you intend to haul a worker through an open window
They must disconnect fro their safety line then before you must
1. Attach snap hook of LSR to workers harness 2. Secure LSR to substantial object
If determined that a stalled scaffold is due to overheated motor then
Allow to cool for 15 min
Then have worker press reset button
You will never need to lower a member by LSR to reach stranded workers
Generally not ( not never ) Says unless workers endanger of falling or some other imminently dangerous condition dictates immediate action removal will be accomplished with high angle rope
Tactics occupied hanging or off level suspended scaffold
Usually caused by one hoist motor stopping while other continues
Locate window nearest scaffold
Communicate with trapped workers ascertain state
Send team to roof to inspect anchoring system secure if necessary
Without going out on scaffolding attempt to attach LSR onto victims harness (victim may help) anchor other end to substantial object either inside or on roof
If possible haul In Through window or create mechanical advantage