Pak Tracker Flashcards

0
Q

Max range of the PAK tracker is

A

900 feet line of sight

Range is dependent on environmental conditions and anything that would cause interference or reflection of the personnel transmitter signal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

The PAK tracker is used to locate a signal from

A

SCBA whose PASS alarm is in full alarm mode for 10 seconds

Note PAK tracker will emit 2-tone audible alarm when transmitted signal is received and display the id ( unit and member assignment ) of SCBA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Is the PAK tracker intrinsically safe

A

No it is not suitable for use in potentially flammable or explosive atmospheres

Always check first

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

To turn on the PAK tracker

A

Press and hold both the ENTER (right) and SCROLL (left) buttons at same time

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The PAK tracker can store up to how many SCBA identities

A

36

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

The receivers LCD screen is large enough to display

A

Two lines of information

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

If two SCBAs pass alarms activate they will bOth show on the screen if a third SCBA activates

A

Then it will show at the top of screen and the first SCBA will move off
The latest activation will be on top
Use scroll button on left to view all SCBA

Note a downward pointing arrow indicates more than two pass alarms activated

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The PAK tracker can lock on to how many SCBA pass signals at once

A

One

There is a 10 second time lag built into system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The strength of the PAK tracker signal will vary depending on

A
  1. Distance from SCBA
  2. Path the SCBA signal has taken to get to PAK tracker
    3 materials between the SCBA, and the PAK tracker which may affect the signal from the SCBA
  3. Orientation of the hand held receiver
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Procedure to track an SCBA

A

If a SCBA pass is activated it will appear on PAK tracker if you wanna track press and hold enter button once

If more than two SCBAs activated press and hold scroll button (left) for 3 seconds and continue to hold until activated pass you want to track is on top of screen , release. Scroll and press enter once to select that SCBA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

When you begin searching the PAK tracker should be held

A

Horizontally At waist level out in front of operator
Top of hand held receiver should be printed toward target

Should be held horizontally first and the. Vertically if signal is suspected may be coming from higher or lower floor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

When will the led lights be in to illuminate on the PAK tracker

A

When signal rises above 50%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

You should pause how long for a reading

A

Always pause 3-4 seconds for reading

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

The signal from the SCBA or the PAK tracker will usually pass through

A

Openings such as gaps holes stairways windows elevator shafts
Glass
Wood
Light building materials

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

The signal will reflect and or not penetrate through

A

Metal including structural framework
Large metal objects
Concrete walls or floors
Brick or concrete block construction

Note signal will attempt to pass around these objects

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

The ember operating the PAK tracker should be where relative to the search team

A

In the front of search team

16
Q

The PAK tracker should be tested and inspected

A

Before each use and at the start of each tour

If OOS rt-2 to MSU

17
Q

When the low battery indicator on PAK tracker glows yellow it means the

A

PAK tracker has approximately 20 percent of its life remaining

If low battery indicator comes on the PAK tracker will operate for approximately one hour

18
Q

Batteries should be charge

A

On reg basis such as once a week

After use

19
Q

If light in charger base glows yellow

A

Charger in stand bye mode

20
Q

If light on charger flashes red as son as battery is place in it

A

Indicates defect in battery

Remove battery and dispose of

21
Q

PAK tracker should be cleaned when necessary using

A

Cloth dampened with solution of mild detergent.

Do not immerse spray or douse PAK tracker in liquids

22
Q

If storing PAK tracker for extended time

A

Remove battery pack

23
Q

Who will be assigned the Pak- tracker

A

A member of fast other than member monitoring EFAS

24
Q

When the Pak tracker receives an alarm the FAST member monitoring the PAK TRACKER will notify

A

Company officer with ID on screen (members unit and assignment )

25
Q

When the officer of the fast team is informed by the member monitoring the Pak tracker that Pak tracker has alarmed . What should he do ?

A
  1. Notify IC of activation
  2. Attempt to contact the member to determine whether the signal is for emergency or inadvertent activation
  3. If activation for life threatening emergency or if no contact can be established , the fast unit officer shall immediately notify IC with mayday transmission.
26
Q

When more than two Pak tracker are activate how do you scroll to see the additional SCBA identities

A

Press and hold the scroll button on left for 3 seconds
After 3 seconds the id s will begin to scroll on LCD screen
When desired ID pears in top row release scroll button

27
Q

Defective batteries sent too

A

MSU