How many feet on the side of the rear mount aerial do you need to put stabilizers down

A

5.2 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

The load capacity of the aerial varies from ____lbs to ___ at the tip depending on the degree of elevation

A

250 to 750

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Dimensions of rearmount

A
36 feet long 
8 ' wide with stabilizers nested 
18.4 with stabilizers down 
10'8" high 
60,000 ibs unloaded
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Sequence for activating PTO on rearmount aerials

A
  1. Place transmission into neutral
  2. Engage maxi- brake
  3. Move front brake lock switch to on position ( front brake light will illuminate )
  4. Open red cover of PTO control switch and flip to up position .. PTO light on
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

True or false the aerial ladder must be bedded and stabilizers fully nested to disengage PTO

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Sequence for disengaging PTO

A
  1. Bed aerial ladder and nest stabilizers
  2. Store wheel chocks and stabilizer pads and make sure all compartments closed
  3. Close red cover of PTO control switch
  4. Move front brake lock switch to off position
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

The interlock diverted valve allows the aerial ladder to move when the stabilizers are properly engaged . Can you override the IDV

A

Yes in emergency if there is a malfunction and emergency exists and stability of apparatus and safety of all persons and equipment is considered

Inform IC immediately if IDV override is operated

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

When extending and lowering stabilizers you should start with

A

The stabilizer on the working side (inboard ) first

Note .. Exception if aerial is not level start with low side first .. This may or may not be inboard side depending on position of rig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Short jacked means

A

A stabilizer that is not fully extended horizontally

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

When should the ground stabilizer pads be placed on the ground

A

Right before stabilizers contact ground

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

When ground is not level and apparatus leaning you should lower which side first

A

On lowest side first(direction apparatus leaning)

Note :
lower the low side stabilizer fully
Lower the high side as necessary to a point that levels apparatus ( use inclinometer )
If the inboard side is the high side then it must be fully extended horizontally than lower the distance to level apparatus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Manual safety pins should be placed where

A

In the highest hole possible in the stabilizer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

How can you tell how far the ladder is extended form the pedestal of the aerial

A

When the extension footage numbers on the base section vertical struts and the corresponding bright colored vertical strut of second section line up ladder is that length

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

When should the aerial emergency hydraulic operation be used

A

When normal PTO fails or the engine shuts down and the aerial ladder or jacks need to be used

May not work if aerial losses hydraulic fluid ..however still make attempt. Reason for failure must be addressed before the emergency system can function

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

The engine should be running when the normal/hydraulic switch his placed into auxiliary position

A

False cannot be running

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Steps for emergency aerial ladder operations

A
  1. With engine off place ignition ON and place transmission in neutral and apply all brakes
  2. On aerial control panel place PTO switch to ON and move the normal/emergency switch to auxiliary position? (Red indicator light will illuminate )
  3. At pedestal depress aerial enable for switch
  4. Activate the emergency pump switch ( this is a momentary switch ,which means it must hold switch in ON POSITION) and at same time activate the function that u want to perform
  5. Once ladder has completed that function release both control lever and emergency pump switch and allow for cool down period before attempting another function
16
Q

When you activate the emergency pump switch you must continually hold the switch until the ladder has completed tins function

A

True is momentary toggle switch

17
Q

The rotation limiting device limits turntable rotation on the short jacked side too

A

No more than 15 degrees from center line

18
Q

When may you override the rotation limit switch

A

If mechanical malfunction occurs and you have confirmed that the stabilizer are fully extended horizontally and loaded vertically

Alarm will sound when using switch
Light will illuminate ate
Only when absolutely necessary

19
Q

If there a malfunction of rotation limit switch

A

Notify fleet services ASAP

20
Q

How many ff do you need to place stabilizers for aerial ladder

A

One

21
Q

What are the 2 functions of the interlock diverter valve

A
  1. When ground stabilizers are loaded vertically the aerial interlock valve opens and allows movement of aerial
  2. When the aerial ladder is moved from cradle ,it closes the stabilizer interlock valve and prevents movement of the stabilizers
22
Q

Points about lowering stabilizers on Un level ground

A
  1. Start with stabilizer on low side first (regardless if inboard or outboard side)…low side is direction that apparatus leaning
  2. Low side stabilizer shall be fully extended horizontally and lowered to max
  3. High side is extended as necessary and lowered to point that levels apparatus( utilize inclinometer at rear of apparatus )
  4. If inboard side is high side it must be fully extended horizontally and lowered the distance necessary
23
Q

You should match these two things to get the proper load capacity of the aerial

A

The inclinometer ( located on the inside of aerial base section) and the extension footage numbers

24
Q

When using the aerial emergency hydraulic operation you must perform each function with a deliberate no rush approach . You should perform each function consecutively with no rest .

A

No when you perform a function ( retract, lower, rotate) you must wait a period so the batteries and electric pump can cool down