Masonry Flashing Flashcards
slope of the coping called
the wash
tops of walls/parapet flashed,
and capped w
coping
base flashing installed at bottom of exterior wythe,
extend …
up 8-10” and set in joint in interior wythe.
weep holes located
24” OC horizontally,
in lowest course of brick.
and over windows,
+ shelf angles.
today openings are typ. spanned w:
steel lintels
alts to steel lintels
concrete beam,
or masonry bond beam.
(fully grouted/reinforced)
lintel carries load in triangular area w in __º from each side of opening
60
white deposit of salts
Efflorescence
efflorescence caused by
materials w soluble salts
efflorescence removed by
dry brushing,
or washing w 5% solution muriatic acid.
@ completion of a job, brick cleaned w
5-10% solution muriatic acid
problem w High Pressure Washing
may wash away mortar and create swirls
Water and Brush are best cleaners for
soft brick
used for cleaning stubborn dirt/stains
Acid Solutions
technique used if mortar has fallen out
mortar removed to about 2.5x width of the joint,
cleaned, wetted,
new mortar pressed in,
w special tool.