HDSO - Loss of Hydrogen Flashcards
1.1 IMMEDIATE ACTIONS
1.1.1 - IF Light HDS Unit pressure is lost, CHECK TDC3000 Console for the following:
CCR
*Tail Gas pressure in 630/631 Unit less than 360 psig, as indicated by Tail Gas Pressure Indicator Controller (60PC0005)
CCR
*630/631 Unit Hydrogen Feed pressure less than 215 psig, as indicated by Hydrogen Feed Presure Controller (62PC0350)
CCR
*Tail Gas pressure in 632 Unit less than 450 psig, as indicated by Tail Gas Pressure Indicator Controller (62PC0302A)
Oper 1.1.2 - VISUALLY VERIFY appropriate Feed Hydrogen & Recycle Compressor(s) are RUNNING.
Oper 1.1.3 - VISUALLY MONITOR appropriate Feed Hydrogen & Recycle Compressor(s) Make-up Discharge Bottle Local Temperature Indicator.
Oper 1.1.4 - IF Feed Hydrogen & Recycle Compressor Make-up Discharge Bottle UNLOAD the Makeup end of Compressor.
1.1.5 - IF pressure indications on the following applicable units are NOT EQUAL, PERFORM HDSO-EOP-5018 Gas Leaks procedure:
Oper
*Hydrogen Feed pressure Indicator located on Feed Hydrogen Compressor Suction Knockout Drum
Oper
*Make-up Drum pressure, as indicated by Local Pressure Gauge
Oper
*Hydrogen & Recycle Compressor Suction Bottle pressure, as indicated by Local Pressure Gauge
1.2 SUPPLEMENTAL ACTIONS
1.2.1 - NOTIFY the following of loss of Light HDS Unit pressure or Hydrogen:
CCR/Oper
*Shift Supervisor
*BBC Console Operator
*Coker Console Operator
1.2.2 - IF pressure indications in Step 1.1.5 are EQUAL, PERFORM the following for applicable unit:
CCR A. REDUCE Feed Rate to 630/631 HDS Units.
B. ENSURE the following pressure controllers are OPERATIONAL:
CCR/Oper
*Tail Gas Pressure Controller for 630/631 Unit (60PC0005)
*Tail Gas Pressure Controller for 632 HDS Unit (62PC0302)
CCR
C. CLOSE Flow Controller (62FC0100), to cut feed to 632 HDS Unit.
CCR
D. IF Light HDS Unit pressure is lost, OPEN Divert Valve (MOV-4), to divert excess feed to 815 Tank.
1.2.3 - IF Hydrogen flow to Light HDS is lost, ENSURE the SIS CLOSED Fuel Gas Supply isolation valves for appropriate Rx Feed Heater(s):
Oper
*Rx Feed Heater (630F0001)
*Rx Feed Heater (631F0002)
*632 Rx Heater (632F0001)
*632 LEF Reboiler Heater (632F0002)
CCR/Oper/Fuel Dept
1.2.4 - COORDINATE replacement Hydrogen from Air Products or Channelview.
1.2.5 - IF Light HDS Unit pressure is DECREASING, or Hydrogen flow is NOT RESTORED, PERFORM the following Emergency Shutdown procedures:
CCR/OPER
*60-EOP-5001, 630 HDS Unit Emergency Shutdown
*61-EOP-5002, 631 HDS Unit Emergency Shutdown
*62-EOP-5001, Emergency Shutdown
THIS IS THE END OF THE PROCEDURE