1.1 IMMEDIATE ACTIONS

CCR 1.1.1 - INFORM 637 Operator of the loss of cooling water to 534

CCR 1.1.2 - IF cooling water isn’t restored immediately, PLACE PC1016 Depentanizer Reboiler Heater Fuel Gas Controller in MANUAL mode and close the fuel gas regulator.

CCR/Oper 1.1.3 - VENT Depentanizer Tower to Low Line as needed to prevent lifting Relief valve to the 534D0025 Flare Drum

A

Oper 1.1.4 - Bypass unit by opening valve on feed bypass line to 632 Unit located at East Plot Edge.

Oper 1.1.5 - SHUT DOWN Depentanizer Feed Pump (534P0029/A).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

CCR 1.1.6 - Place the following Controllers in MANUAL and CLOSE:

A

-Depentanizer Feed Flow Controller (54FC0035)
-Depentanizer Bottoms Flow Controller (54FC0045)
-Depentanizer Reboiler Heater Fuel Gas Controller (54PC1016)
-Depentanizer Overhead Flow Controller (54FC0052)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Oper 1.1.7 - WHEN level in Depentanizer Accumulator (534D0023), is less than 20%, as indicated by Level Transmitter (54LT0024)

A

SHUT DOWN Reflux Overhead Pumps (534P0027 and 534P0032)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

1.2 SUPPLEMENTAL ACTIONS

Oper 1.2.1 - CLOSE upstream valve on the following Control Valves:

A

-Depentanizer Overhead Flow Controller (54FC0052)
-Depentanizer Bottoms Flow Controller (54FC0045)
-Depentanizer Reboiler Heater Fuel Gas Controller (54PC1016)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Oper 1.2.2 - Close block valves on Fuel Gas line located at each Depentanizer Reboiler Heater Burner.

A

THIS IS THE END OF THE PROCEDURE