1.1 IMMEDIATE ACTIONS

CCR/Oper 1.1.1 - DETERMNE if loss of Reboiler Circulation was due to pump failure, or malfunction of 62FV0115, LEF Reboiler Flow controller.

A

Oper 1.1.2 - IF loss of Reboiler Circulation was due to pump failure, START spare 62P0004A/B, LEF Reboiler Circulation Pump.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

CCR/Oper 1.1.3 - IF loss of Reboiler Circulation was due to Flow controller malfunction, OPEN bypass around 62FV0115, LEF Reboiler Flow controller

A

CCR/Oper 1.1.4 - IF Reboiler Circulation was re-established and the SIS system caused the fuel gas chopper valve to close, RESET 632F0002, LEF Reboiler heater SIS system per, 62-SOP-2028, Heater Operation.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

CCR/Oper 1.1.5 - IF LEF Reboiler Circulation cannot be restored, PERFORM 62-EOP-5001 Emergency Shutdown.

A

THIS IS THE END OF THE PROCEDURE