FERG - Car Parks Incorporating Multi-tiered Vehicle Stacking/Storage Devices Car Stackers Flashcards
1
Q
FERG - Car Stackers - Considerations
A
- Access to vehicles that are recessed into a sub-structure cannot be guaranteed
- Consider using a positive pressure ventilation fan or installed mechanical ventilation system to improve visibility
- Consider a defensive attack
- Consider a foam fire attack
- Concerns with regard to firewater
- Consider building power isolation
- Consider High Angle Rescue
- Consider Safe Working at Heights
2
Q
FERG - Car Stackers - Actions
A
- Isolate electricity to the car stacker. Lock out/tag out function on power supply
- Use electrical current detector to test for live equipment before proceeding with any firefighting operations
- Immediately ascertain if sprinklers have activated if installed
- Regularly conduct SPADRA