EXAM 6 Flashcards
uestion 1:
Every member upon completion of Probationary Firefighter School is issued a composition notebook to document their training. Notebooks shall be maintained until the end of the probationary period. Choose the most correct statement made in regards to the notebook.
A:Members shall ensure a tool list from their current unit is attached to the inside cover of the notebook
B:Notebooks shall be kept in the company office when not in use
C: Company officers shall review their notebooks weekly
D: Monthly training module receipt should be printed and stapled to the last page of training notebook at time of completion
B Explanation:
AUC 323 add 2
A- First page of the notebook….1.3
C- Each tour the member works (Company Commander monthly) (Chiefs during drills)….1.4
D- Monthly training module receipt should be printed and stapled to CURRENT TRAINING NOTEBOOK PAGE at time of completion …..1.5
Question 4:
Units are operating at a fire on the 3rd floor of a 5-story old law tenement. Hoselines are deployed in the following manner. Which line is deployed correctly?
A: In all cases, the first line must be stretched to the 3rd floor via the interior stairs.
B:After receiving a report that the fire is about to extend across a narrow shaft to exposure 2, the IC orders the 2nd line stretched to that exposure.
C: At this fire, the second line is usually stretched by way of the interior stairs to the 4th floor.
D: The 3rd hoseline is usually stretched via the interior stairs to a floor above the fire.
B Explanation:
A. In MOST CASES, the first line is stretched via the interior stairs to the location of the fire. An EXCEPTION to stretching the first line up the interior stairs may be made when FLAME is issuing from windows opening onto the fire escape and endangering people trying to come down the fire escape. In this case, the first line may be operated from the street to protect people on the fire escape. A second line should be promptly stretched to the interior of the building.
C. The second line is usually stretched by way of the interior stairs to THE SAME FLOOR AS THE FIRST LINE. IF NOT NEEDED ON THE ORIGINAL FIRE FLOOR, it is advanced to the floor above.
D. The third line in the building is usually stretched via the FIRE ESCAPE OR ROPE STRETCH via a window.
NOTE B: In some cases, the second or third lines may be urgently needed in one of the exposures. The decision as to the location to which these lines shall be stretched rests with the Incident Commander, and is based on his/her size-up of the fire situation. For example, at a fire in an Old Law Tenement it is often necessary to stretch the second or third line into Exposure 2 or 4 because fire has extended, or is about to extend, across the narrow shaft or shafts between buildings.
Multiple Dwellings 3.2.2; 3.2.11
Question 5:
When discussing Aerial Ladders, the most correct statement made can be found in which choice?
A: Each Aerial stabilizer requires a clearance of 6 feet for full extension
B:Aerial load capacity varies from 250-750 lbs at the tip depending on the degree of elevation
C: When the ground is not level and the apparatus is leaning, start with the stabilizer on the highest side first. The low side stabilizer shall be extended as necessary and then lowered to a point that levels the apparatus
D:The Rung Alignment Indicator Light must be ON before permitting personnel to climb ladder
B Explanation:
Training Bulletins Apparatus L-7
A- 5’ 2”……3.1
B- 1.4
C- When the ground is not level and the apparatus is leaning, start with the stabilizer on the LOWEST side first. The low side stabilizer shall be fully extended horizontally and lowered to its maximum. The HIGH side stabilizer shall be extended as necessary and then lowered to a point that levels the apparatus….
NOTE: If the inboard stabilizer (working side) is also the high side, it must be fully extended horizontally and then lowered the distance necessary to level the apparatus for a safe operation….. 3.3
D- IF POSSIBLE, make sure Rung Alignment Indicator light is ON before permitting personnel to climb ladder….4.3
Question 6:
Mezzanine areas will be found in some taxpayers and their location, area and use will differ. All choices below contain correct information regarding mezzanines in taxpayers except?
A: Some are found in the rear of the store or building, some along one side from front to rear or along part of one side, and a few have been erected in the center of the premises.
B: The height of the ceilings in the mezzanine and the area below will be below average.
C:Access to the mezzanine will usually be via two separate wooden stairways.
D: The majority of mezzanines will not be enclosed and there will be a railing at the edge.
C Explanation:
Access to the mezzanine may be via small wooden stairs or just a ladder. Very seldom will there be another means of access.
Txpyr 2.4
Question 7:
At an extended collapse operation, Ladder 99 was assigned to relieve Ladder 95 and continue with searches. Minutes into their search, they come across an “X” indicating the company had entered and exited the structure. Which choice CORRECTLY indicates the labeling of the quadrants?
A: Ladder 99 was spray painted in the top quadrant, the date and time in the left quadrant, 3 dead victims in the bottom quadrant, and water in the right quadrant.
B: Ladder 99 was spray painted in the bottom quadrant, the date and time in the top quadrant, water in the left quadrant, and 3 dead victims in the right quadrant.
C: Ladder 99 was spray painted in the left quadrant, the date and time in the bottom quadrant, water in the right quadrant, and 3 dead victims in the top quadrant.
D:Ladder 99 was spray painted in the left quadrant, the date and time in the top quadrant, 3 dead victims in the bottom quadrant, and water in the right quadrant.
D Explanation:
FIREFIGHTING PROCEDURES – COLLAPSE ADDENDUM 2
D – Correct – section 4 pgs 2 & 3 – Company designation in the Left Quadrant, Date and Time personnel left in the top quadrant, Personal hazards in the Right Quadrant, Number of live and/or expired victims in the bottom quadrant…
Question 8:
Large capacity ammonia refrigeration systems are provided with an emergency ammonia mixer for the purpose of mixing ammonia with water. Officers in command of fires shall order the use of this device when there is excessive pressure developing in the refrigeration system due to the proximity of the fire. Which statement below is correct regarding this procedure?
A:The mixer is designed to mix the ammonia with water and discharge it into sewer lines.
B: Volume of water to be supplied depends on the capacity of the system and is indicated by the size of the pipe from the siamese or inlet to the mixer. (Pipe 1 ¼ inch to 2 ½ inch requires a volume of 200 to 250 gallons of water per minute)
C: The ECC with the unit supplying the water shall determine the necessary pressure to provide the required volume of water.
D: Control valve boxes shall be opened by a Fire Department alarm box key. Before water is started, the ammonia valve shall be opened fully
A Explanation:
B. …requires a volume of 100 to 700 gallons of water per minute.
C. THE OFFICER ON DUTY with the unit supplying the water…
D. AFTER water is started,…
Regulations Ch 11: 11.5.17
Question 9:
You are 10-84 at an EMS run in apt 14D on the 14th floor where you soon discover what you think is a deceased person. As you look around, you notice the window is open, blood on the floor, and furniture turned over with large sums on money scattered all over the floor. You quickly determine that the scene is considered a crime scene and notify P.D. Since this is now considered a crime scene, you followed which correct FDNY procedure?
A: Refrained from patient care in order to preserve the crime scene
B: Washed hands in sink because one of your FFs had sneezed on their hands
C: After assessing patient covered corpse with a sheet
D:Notified the Fire Marshals
D Explanation:
AUC 317 sec 5
A- Patient care should never be compromised in order to protect the crime scene.
B- Do not wash hands in sinks or use toilet facilities
C- Refrain from covering any corpse except in public view
D- Fire Marshals to respond to voucher currency at any operation where large amounts of currency are discovered
Question 10:
Two members discussing trenching operations at taxpayer fires agreed on all statements below except which incorrect choice?
A: The width of the trench should be at least three feet wide. A trench cut may be made in any direction.
B: Trenching does not take the place of ventilation holes. Although a trench may serve as an additional ventilation source, it’s main purpose is to prevent the fire from passing that point at which the cut is made.
C:It is essential that units trench a large roof area of a taxpayer when fire has seriously involved a major portion of the cockloft to reduce the possibility of extension and possible loss of the building.
D: The Roof Sector Supervisor can start a trench cut where he/she sees the necessity for it. Immediate notification to the Incident Commander of the operation is mandatory.
C Explanation:
It is not practical to trench a large roof area of a taxpayer where fire has seriously involved a major portion of the cockloft. Emphasis must be placed on ventilation holes.
Txpyr 5.6
Question 11:
A sharp Engine Company Officer was conducting a drill with members of her company on water loss procedures and made the following statements. Which one regarding short stretching was CORRECT?
A: If you stretched six lengths of 1 ¾ and end up with a short stretch, a rolled-up length of 1 ¾ can be added to the front of the stretch.
B: If you’re adding 2 ½ hose to the front of a 2 ½ hose stretch, disconnect the OST and connect the 2 ½ directly to the main stream tip of the nozzle.
C: Water shut down at the pumper will be required when adding hose to the front of the stretch.
D:When adding 1 ¾ hose to the front of a 1 ¾ hose stretch, the tip is removed from the original nozzle, and an extra length(s) is added by connecting the female butt to the shut-off
D Explanation:
ENGINE OPERATIONS CHAPTER 12
D- In order to charge the new lead length(s), open the shut off from the original nozzle, which is acting as an in-line gate. NOTE: The Engine Officer will ensure that this shut-off does not accidentally get shut down….4.3
A – if 6 lead lengths of 1 ¾ hose are stretched, only lengths of 2 ½ can be added. 4.1
B – The 1 ½ x 2 ½ increaser is connected to the shut off. 4.5
C – Water Shut down is not required 4.2
Question 12:
The Marine companies carry ___ foot and ___ foot portable hook ladders with wood beams. They are painted ___ except for the hooks and for 18 inches at the base of each beam, which are painted ___.
A: 10; 14; black; white
B:12; 20; black; white
C: 10; 14; white; black
D: 12; 20; white; black
Explanation:
Portable Ladders 1.2
Question 13:
During hot weather, responding without Personal Protective Equipment (PPE) is permissible for all of the following runs except?
A:Non-Structural fires
B: BARS Alarms
C:Class 3 Alarms
D: Class E Alarms
C Explanation:
Non-Structural Fires and Response to BARS Alarms, Non-Fire responses, ERS no contact, and Class E Alarms, and CFR responses
AUC 310 sec 7.2.2
Question 14:
All company officers should know that, in a high rise office building, the HVAC system shall be placed in the non-circulating mode by?
A: Closing all outside air supply dampers; Closing all mixing dampers; and Opening all exhaust dampers.
B:Opening all outside air supply dampers; Closing all mixing dampers; and Opening all exhaust dampers.
C: Closing all outside air supply dampers; Closing all mixing dampers; and Closing all exhaust dampers.
D: Opening all outside air supply dampers; Opening all mixing dampers; and Opening all exhaust dampers.
B Explanation:
Acronym: OO CM OE
Open Outside supply
Close Mixing
Open Exhaust
HROB 3.3.3
Question 15:
Which of the following is INCORRECT regarding operations in buildings with Sprinkler Systems?
A:If a building is equipped with both a Standpipe and Automatic Sprinklers, the first supply line must be stretched to the Sprinkler Siamese to achieve a quick knockdown.
B: If a sprinklered building is not equipped with a standpipe system, the first line stretched should be a handline and the second line used to augment the sprinkler system.
C: Sprinkler systems should always be supplied with 3 ½ hose.
D: If the first due Engine is supplying both the sprinkler and standpipe systems, the second and third due engine companies must stretch additional lines to augment both systems.
A
stretch additional lines to augment both systems.
Explanation:
ENGINE OPERATIONS CHAPTER 10
A - The first supply line must be stretched to the standpipe Siamese. 10.3.3
B – 10.3.4
C – 10.3.2
D – 10.3.3
BackListNext
Question 16:
At an isolated building, when roof access and egress via conventionally positioned aerial ladders would be endangered or impeded by a serious fire condition, officers should consider the following points. Which one is incorrect?
A: Use one of the aerial ladders by having it placed to the least exposed sidewall of the building.
B: This position may require placing the apparatus on the sidewalk.
C:Members should ascend and descend at close intervals.
D: This use of the aerial ladder requires that it initially be placed in the cantilever position with the tip close to the building so that when placed under load it will ether not touch or barely touch the wall.
C Explanation:
C. …at WELL SPACED interval.
Aerial Ladders 3.6
Question 17:
Which of the following is not considered a “Permit Required Confined Space”?
A: Contains or has the potential to contain a hazardous atmosphere
B: Contains material that could potentially engulf a person
C:Is shaped in a way that a person could be caught or asphyxiated by inwardly tapering walls, or floors that slope upward, tapering into a larger cross section
D: Contains any recognized serious health or safety hazard
C Explanation:
Is shaped in a way that a person could be caught or asphyxiated by inwardly tapering walls, or floors that slope DOWNWARD, tapering into a SMALLER cross section
A permit space is designated by the owner of the space, who issues the permit. They may be recognized by the warning sign which OSHA requires to be posted at the entry to the space reading: Danger: Permit Required Confined Space-Do Not Enter or similar wording
Training Bulletins Confined Space sec 1.2