The facility _____ is a detailed arrangement of kitchen equipment, floor, and counter space
Layout
The facility ____ is the overall space planning
Design
The first step in planning the layout is to prepare a ____, or a planning guide, which is a formal summary of proposed work
Prospectus
The next step in planning a facility is to organize a planning ____; includes an administrator (final approval), food service manager, architect, design consultant, equipment representatives, builder, and mechanical engineer)
Team
The team should ____ each other on their own area of expertise to prevent them from making mistakes
Educate
The next step would be to conduct a ____ study is research and data analysis to justify a project
Feasibility
The next step would be to analyze the ____; determine the type, food prep methods, equipment, and space
Menu
____, or the environmental design, is part of human engineering
Ergonomics
Ergonomics studies activities so they are done safely and _____
Efficiently
What are examples of ergonomics?
-Comfortable seating
-Noise control
-Mobile equipment
-Close storage areas
-Easy entrance and exit
-Place work areas to facilitate smooth flow patterns
The space required is determined by the “___ ___” of foods purchased (raw, prepared, partially prepared)
Market form
Equipment required is based on the ____ (size of batches of food and frequency)
Menu
Walls of a food service facility should be made of ____ ____ 5’8” high; washable, and impervious to moisture
Glazed tile
Ceilings of a food service facility should be _____ treated, lighter in color than the walls, and 14-18’ high
Acoustically
Floors should be…
-Resilient
-Durable
-Non-slippery
____ can be used for areas of light traffic like storerooms and receiving areas; it absorbs grease
Concrete
_____ is a flooring material made of cement and crushed marble; it is noisy and sometimes used in a dining room
Terrazzo
The best option for kitchen flooring is ____ ____ (unglazed red clay tiles); used in high-traffic areas
Quarry tile
_____ can be used for flooring in light traffic areas like the dining room
Asphalt
_____ is also very important in a food service establishment; temperature should be kept at 68 degrees F; should include a fan system to eliminate cooking odors and moisture
Ventilation
Lighting intensity is measured in ____-____ (how bright the light is one foot away from the source)
Foot candles
There should be at least ____ foot candles in dry storage areas
10
There should be a minimum of ____ foot candles in handwashing and dishwashing areas, and self-service food areas
20
There should be at least ____ foot candles in food preparation and display areas (general lighting)
50
There should be ____-____ foot candles in localized detail work areas and areas where recipes will be read
70-100
A ____ ____ shows steps the worker must take, their sequence, and the relation of working units to each other
Flow chart
A typical food service flow chart design has little cross ____ and no _____
Traffic; backtracking
_____ are models of equipment cut to scale to use in layouts
Templates
In a cafeteria, there should be at least ____ inches between chairs and tables should be ___-___ feet apart
18; 4-5
Serving width should be ____ feet (4 foot patron line, 1 foot tray slide, 2 foot counter width, 4.5 foot workers, 2.5 foot back-bar)
14
Employee dining should include ____ square feet per person
12
A kitchen aisle space with a lane for 1 person should be between ____-____ inches
36-42
A kitchen aisle space with a lane for >1 person, or where mobile equipment passes through should be between ____-____ inches
48-52
A main traffic lane in a kitchen should be ____ inches
60
The floor area should include ___-___ square feet per bed
20-30
Optimum counter height for heavy work is ____ inches; for light work it is ___-___ inches
36; 37-41
There should be a minimum of ____ inches between the floor and the bottom of heavy-duty equipment for cleaning purposes
6
There should be a ___-___ inch clearance of heavy equipment from the wall
12-24
A ____ ____ layout for a work area is the best from a time and motion point
Straight line
An ____-shaped layout is used when there is a limited amount of space; convenient work surface
L
A ____-shaped layout includes large amounts of table surface area but walking in and out adds steps
U
A ____ and back-to-back ____ layout are very efficient
Parallel; parallel
Specifications of electrical equipment include…
-Voltage
-Watts
-Type of current
Specification for gas equipment is the ___ ___ ___
British Thermal Unit
Specification for steam equipment is _____
PSI (pounds per square inch)
Equipment includes a _____, which explains what will be covered and for how long
Warranty
The National Sanitation Foundation International conducts voluntary inspections of _____
Equipment
The National Sanitation Foundation International complies with ____ ___ and ____ standards
Food safety and sanitation
Equipment deemed safe is acceptable in…
-Design
-Materials
-Construction
-Performance
Corners and edges should be ____ and tightly sealed; surfaces should be smooth and free of crevices; should be easy to clean, maintain, and service
Rounded
____ ____ conducts voluntary inspections of electrical equipment
Underwriter’s Laboratories
Stainless steel is ____ and wears well
Durable