AUC 274 Satellite Water System Flashcards
Primary purpose of satellite unit is to
Provide IC with dependable high volume supply of water
Satellite unit consists of
Satellite apparatus and the companion 2000 GPM engine
Satellite officer
First arriving satellite officer is water resource officer
He will coordinate the activities of all satellites at operation
The primary concern of sat officer is to consult and advise the IC on water delivery demands
If delivery of water is not a problem IC may use nit in any capacity for mitigating fire or emergency
What is the primary concern for satellite officer
Consult and advise the IC on Water delivery matters
Description of satellite apparatus
Hose wagon with mounted intelligent deluge guns, deck pipes and supply of 5” hose
When using sat apparatus and connecting multiple lines use
Unchecked inlets first then gated to augment the supply without the necessity of shutting down
When responding with the satellite apparatus and the pumper how will each apparatus be staffed
At least two ff on each apparatus
Officer rides with pumper
Upon arrival at the scene
First sat officer is water resource officer
Report to IC for doses and instructions
Upon orders of IC coordinates use of all sat units at scene
In addition the officer will advise the IC to special call a foam apparatus to supply sat when bulk foam needed at op
The water resource officer will establish HT communications with the IC through established
Communications lines. The priority would be through
Field comm unit if on scene
What shall the sat officer do immediately upon receipt of an alarm
Immediately consult the water maps and select locations of one or more hook up sites for units of sat system
What is the best position of sat apparatus when using deluge guns
Apparatus far enough from building so as to permit the deepest possible penetration
When using the sat system to supply foam a modified angus foam cannon can be attached to the deluge gun or the TL . These streams may be capable of reaching ?
Deluge gun 250 feet
TL 300 feet
When using a hydrant with a main less the 12”(common in the Jamaica water system ) it is recommend
That a second hydrant or another pumper augment the water supply. A second source is necessary to reach max utilization of sat pumpers full capacity
Good nozzle pressure for sat deluge guns
125 psi for 2” and 2 1/2 “ tips
100 psi for 3” and 3 1/2 “ tips
Whenever a sat unit leaves or enters quarters what shall be done
One member must be assigned to make sure the deluge gun is placed so that it clears the doorframe