AUC 150 Iroquois Flashcards
When closing the gas valve by using the reserve gas what should you check first
The valve flow indicator valve
If in closed position no further action necessary
What is the primary method to close valve in Iroquois pipeline
To use the reserve gas to close by pushing red handle
Valves shall not be shut without consulting IC unless
Immediate threat to life or property
Shutting manually valve will take
213 turns
Patrolling of valves for leaks will only be conducted by rescue , squad or soc support t
Should be but if not available IC can designate another unit
Marine companies for sub level sea leak
To use the manual pump handle
Turn red handle to 9 o’clock position
Insert pump handle
Begin pumping
Initial actions of units responding to Iroquois pipeline boxes are too
Set up a perimeter and eliminate sources of ignition
The primary consideration at a Iroquois pipeline leak is
Evacuation of area involved
Avenues of escape must remain open for civilians and FD personnel