Reactor Recirc Flashcards

1
Q

WHat are the RR Motor limitations?

A

Normal Ops: Current limit of 770Amps
Coast Down: Limit of 800Amps
Motor Winding Temps limited to 248F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are teh start limitations for RR Pump?

A
Initial Start (Ambient Temp)
2 successive attempts without time limit

Running for 15 minutes:
1 restart attempt without limit

Running <15 minutes:
Subsequent start requires 45 min cooling period

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What are the temp limitations for RR starts?

A

Temp difference between bottom head coolant and RPV coolant less than or equal to 145F

Temp difference between RR Loop coolant in loop to be started and RPV coolant less than or equal to 50F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What are the limitations for starting second RR Pp?

A

RR speed is less than 30% for operating pump

Verify temp difference between active and inactive is less than 50 F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What may happen to RPV level when starting RR Pp?

A

Level may drop up to 6 inches in downcomer region

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the sequence of events observed when taking RR Pump Control Switch to STart?

A
Start Signal
Ready to Run Light Extinguished
Drive ramps to 20% at 5%/second
Running Light Lit
Drive ramps to 30% at 2.5%/second
Raise/Lower Commands locked out until 30% speed reached
Increase/Decrease Commands Enabled
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Why is RR Pp Discharge Vlv opened slowly after RR Pp started?

A

To avoid large flow changes and sudden introduction of “cool” water into RPV

Cool water could cause power spiking

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

When shutting down RR Pp why must FCL be less than 55% PRIRO TO SHUTTING DOWN Pp?

A

If above 55%, likely to enter unstable region immediately

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Why must RR Pp discharge vlv (5A(B)) be in dual indication w/in 2 minutes of Pp Start?

A

Ensures not dead-headed for long period.

Dead-heading results in axial thrust

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Why must seal purge be shut down when shutting down RR Pp?

A

Do not shutdown prior to shutting down. If it is shutdown, seal purge is the only method of cooling. If RR is isolated from Rx, then isolate seal purge just prior to isolating the loop, otherwise blowout seals

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Why is discharge vlv open after pump stops turning?

A

To maintain idle loop temps

How well did you know this?
1
Not at all
2
3
4
5
Perfectly