Condensate Flashcards

1
Q

What is the Condensate Pump Low Amp Requirement (why?

A

160 Amps to ensure pump min flow limit requirements are met.

125amps for upt to 4 hours during startup/shutdown/testing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is the C/CB High Amp Limit?

A

255Amp to prevent winding damage

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Why are there C/CB Low flow limits?

A

low flow rates cause damage from flow instabilities.

Min flow valve operated to minimize this impact

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Why is HAS isolation closed when cond. pump secured?

A

Prevent H2 buildup in idle pump bowl from leak by - causes binding
Prevents H2 system trip on high area concentration when venting pump

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the relief vavle setpoint for the FW Heaters and CB pump suction?

A

FWH - 450psig

CB Suction - 200psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Is there a low suction pressure interlock on C/CB pump?

A

No

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is the minimu suction pressure for RFP?

A

100psi at all times when pumps are running

How well did you know this?
1
Not at all
2
3
4
5
Perfectly