PDX_02_ADA Dimensional Standards Flashcards
2 wheelchair passing width
60 inches minimum clear
Wheelchair passage width
32 inches clear at a point
36 inches clear continuous
Headroom
80” minimum
Turning space
5 foot circle minimum
Clear floor space
2’6” wide by 4’0” long min
Cross slope of a ramp
1:50 maximum
Door opening width
32 inches clear minimum when open 90°
Door clearance
1’6” clear on the pull side of door
1 foot clear on the push side of door
Change in level
1/4” max without edge treatment
Beveled edge is okay on the level change between
1/4” - 1/2” w 1:2 max slope
Level change that requires a ramp
Half-inch or more
Ramp slope
1:20 min - 1:12 max
Ramp with
3’0” wide minimum
Maximum ramp length
30’0” maximum
Ramp landings
5’0” at each end x width of ramp
Ramp needs 2 handrails when:
Rise is greater than 6 inches
Or run is greater than 72 inches
Handrail height is between
34” - 38”
Handrail cross-section has diameter between ____ and clear from wall ____.
Diameter 1-1/4” to 2”
1-1/2” clr from wall
Handrail must extend this distance at the top and bottom of stair or ramp
12” past top and 12” + one tread at the bottom
Clearance required between handrails minimum
48” clear
Knee clearance for wheelchair under a desk
27” high minimum
8” deep at top
11” deep at bottom