Unit 3 is at 100% power with all systems in their normal lineup.
RU-31, Fuel Pool Area Monitor, has a HIGH alarm.
An RCS leak causes a reactor trip, SIAS, and CIAS.
Fuel Building Essential AFU HFB-J01 is ___(1)___. HFA-J01 is aligned to ___(2)___.
A. (1) running; (2) the Fuel Building
B. (1) running; (2) the Aux Building
C. (1) not running; (2) the Fuel Building
D. (1) not running; (2) the Aux Building

A

B

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Of the fuel building exhaust and supply units, which has the higher capacity and why?

A

Exhaust has the higher capacity to maintain a negative pressure on the fuel building.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the location of the fuel building AHUs?

A

Aux building roof near the elevator.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is the location of the fuel building normal exhaust units?

A

Fuel Building roof.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Describe the fuel building ventilation isolation damper arrangement.

A

There are 8 dampers total, 4 for the supply and 4 for exhaust isolation. They are arranged in two sets of two dampers in series on both supply and exhaust sides of the ventilation, and each line has one ‘A’ train valve and one ‘B’ train valve for redundancy.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the location of the Fuel Building essential AFUs?

A

100’ of the Fuel Building.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Where do the Fuel Building AFUs take suction?

A

From either the Fuel Building or the of the Aux Building.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What tanks are vented to the Fuel Building HVAC?

A

RWT and HUT are both vented to HF system.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What occurs when exhaust plenum temperature decreases to 65F?

A

The AHU heaters will turn on to heat the Fuel Building.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What occurs on a low flow in the HF system?

A

Heaters will be turned off to protect from overheating

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q
Fuel Building Normal Exhaust AHUs are powered from which of the following?
A.  NHN-M04
B.  PHA-M33
C.  NGN-L04
D.  PGA-L31
A

A

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Unit 3 is at 100% power with all systems in a normal lineup.
‘B’ train FBEVAS is actuated from B05.
___(1)___ Fuel Building Normal Supply and Exhaust isolation dampers are closed, and the Fuel Building Normal Supply and Exhaust fans are ___(2)___.
A. (1) ONLY ‘B’ Train; (2) running
B. (1) ONLY ‘B’ Train; (2) not running
C. (1) BOTH ‘A’ & ‘B’ Train; (2) running
D. (1) BOTH ‘A’ & ‘B’ Train; (2) not running

A

A

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q
What is the power supply to Fuel Building Essential Air Handling Unit HFA-J01?
A.  PGA-L31
B.  NGN-M04
C.  PHA-M37
D.  NHN-M04
A

C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q
Which of the following is vented to the Fuel Building Exhaust header?
A.  Recycle Monitor Tanks
B.  CVCS Hold-up Tank
C.  Liquid Radwaste TDS Tanks
D.  Reactor Makeup Water Tank
A

B

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Complete the following statement concerning Fuel Building Normal HVAC:
A greater or equal number of ___(1)___ fans than ___(2)___ fans must be running to maintain the Fuel Building at a ___(3)___ pressure relative to atmosphere.
A. (1) supply; (2) exhaust; (3) positive
B. (1) supply; (2) exhaust; (3) negative
C. (1) exhaust; (2) supply; (3) positive
D. (1) exhaust; (2) supply; (3) negative

A

D

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

‘B’ FBEVIAS actuates. What is the status os the fuel building normals AHUs and exhaust units? Assume the ‘A’ FBEVIAS failed to receive the cross trip.

A

Still running dead headed, only ‘A’ FBEVIAS secures the normal air handlers.

17
Q

What is the purpose of the charcoal in the Fuel Building essential air filtration unit?

A

The charcoal adsorbs gaseous iodine prior to exhausting air to outside through fuel building exhaust plenum.

18
Q

What is the purpose of the heaters on the inlet of the Fuel Building Essentials?

A

Keep humidity <70% to allow the charcoal to operate at peak efficiency.

19
Q

Why aren’t the fuel building exhaust units equipped with filtration?

A

The exhaust plenum is monitored by RU monitors to detect any potential release of radioactivity. Activity detected above the set-point will actuate FBEVIAS, isolating the release.

21
Q

SIAS and FBEVIAS occur simultaneously. What mode are the Fuel Building essentials running in? What is the status of the Normal Fuel Building ventilation? Last, what will happen if the SIAS is cleared and reset?

A

Both Fuel Building Essentials will be running taking a suction on the of the Aux building, and the Fuel Building normals will be secured and isolated.
When the SIAS is reset, the suction dampers will realign to the Fuel Building.

22
Q

How many trains of PREACS are required to be operable?

A

2 trains of the Pump Room Essential Air Cleanup System are required to meet tech spec 3.7.13 requirements.