CVCS Flashcards
CHB-UV-515 will close on which of the following?
- SIAS
- CIAS
- CSAS
- Regenerative HX outlet temp. HI @ 413F
- LDHX outlet temp HI @ 135F
- SIAS
- Regen HX outlet temp. HI @ 413 F
What will cause CHA-UV-516 to close?
SIAS
CIAS
Loss of IA/Loss of PK to solenoid
What two valves are Tech Spec containment isolation valves?
CHA-UV-516 & CHB-UV-523
What valve(s) will change position on a high temp of 135F?
CHB-UV-523 goes closed
CHE-UV-521 bypasses the boronometer
CHE-UV-520 bypasses the ion exchangers
What in the Letdown System tells us that we have fuel failure?
RU-155D
What will auto close CHE-PV-201P/Q?
High temperature of 148F sensed at TE 224
Unit 3 is at 100% power with all systems in a normal lineup.
Charging Mode Selector CHN-HS-4 is in 2-3-1.
CHE-P01 is powered from its ‘A’ power supply.
Startup Transformer NAN-X02 trips on sudden pressure.
All equipment operates as designed.
What is the status of the charging pumps?
A. CHE-P01 is running. CHB-P01 is anti-pumped.
B. CHE-P01 is running. CHB-P01 stopped but can auto-start.
C. CHB-P01 is running. CHE-P01 is anti-pumped.
D. CHB-P01 is running. CHE-P01 stopped but can auto-start.
C
Unit 1 was at 100% power with all systems in a normal lineup.
Charging Mode Selector CHN-HS-4 is in 2-3-1.
CHE-P01 is powered from its ‘A’ power supply.
Palo Verde had a loss of all offsite power.
All equipment operated as designed.
What is the status of the charging pumps?
A. CHB-P01 and CHE-P01 are anti-pumped.
B. CHB-P01 and CHE-P01 stopped but can auto-start.
C. CHB-P01 stopped but can auto-start. CHE-P01 is anti-pumped.
D. CHB-P01 is anti-pumped. CHE-P01 stopped but can auto-start.
D
Unit 1 is at 100% power with all systems in a normal lineup.
VCT level transmitter CHN-LT-227 fails high.
With no operator action, what is the expected plant response?
A. Boration will start through CHN-UV-514
B. Charging pumps will trip on low suction pressure
C. VCT level will be maintained between 34% and 44%
D. Letdown will isolate
C
Unit 1 is at 100% power with all systems in a normal lineup.
An RCS leak develops, causing the CRS to enter 40AO-9ZZ02, Excessive RCS Leakage.
VCT auto makeup is disabled to perform a leak rate determination.
VCT level drops to 5%.
With no further operator action, which of the following automatic actions will occur?
A. VCT inlet valve CHN-UV-500 will divert to the PHIX.
B. Makeup Supply to Charging Pumps CHN-UV-527 will open.
C. BAMP recirculation valve CHN-UV-510 will close.
D. Gravity Feed to Charging Pumps CHE-UV-536 will open.
C
Which of the following is NOT credited as a boration flow path per TRM 3.1.101, Flow Paths - Operating? A. From RWT or SFP through CHE-UV-536 B. From RWT through CHB-V327 C. From RWT through CHN-UV-527 D. From RWT or SFP through CHN-V164
C
Unit 2 is at 100% power with all systems in a normal lineup.
An improper valve lineup during a HPSI ST causes the RWT to dump water into the ‘A’ ESF sump. After the cause has been corrected, the RO notes RWT level is 60%.
Which of the following methods can be used immediately if boration is required?
A. Align charging pumps to CHB-V327
B. Align charging pumps to CHE-UV-536
C. Align charging pumps to CHN-UV-514, bypassing the boric acid makeup pump filter.
D. Inject to the RCS with a HPSI pump.
A
Unit 3 is at 100% power with all systems in a normal lineup.
VCT level transmitter CHN-LT-226 fails low.
With no operator action, which of the following automatic actions will occur?
A. VCT outlet isolation CHE-UV-501 will close
B. VCT inlet CHN-UV-500 will divert letdown to the PHIX
C. Makeup to Charging Pumps CHN-UV-527 will open
D. Charging Pumps will trip on low suction pressure
B
Unit 1 was at 100% power with all systems in a normal lineup.
The reactor trips, and three full strength CEAs stick out.
PBA-S03 faults and is de-energized.
The CRS directs the RO to borate the RCS.
Which of the following standard appendices can be used to borate the RCS from the control room?
A. 103-A: BAMP, through CHN-FV-210Y and CHN-UV-527, to charging pump suction.
B. 103-D: RWT gravity feed to charging pump suction by opening CHE-UV-536 and closing CHE-UV-501
C. 10: RWT gravity feed to charging pump suction through CHB-V327
D. 11: SFP gravity feed to charging pump suction through CHE-UV-536
A
Which of the following does NOT discharge to the Reactor Drain Tank?
A. Pressurizer safety valves
B. RCP vapor seal leakoff
C. Gravity drains from the recycle drain header
D. Pressurizer and Reactor Vessel Head vents
C
Unit 3 was at 100% power with all systems in a normal lineup.
A fuse failure causes an inadvertent actuation of ‘B’ train CSAS.
Operators secure ‘B’ CS pump and restore NC to containment.
No further operator action is taken.
Which of the following statements is true?
A. RDT level is going up. VCT level will be maintained automatically between 34% and 44%.
B. Charging pumps tripped off and restarted 40 seconds after the CSAS.
C. RCP seal injection flow control valves have failed open.
D. Letdown isolated due to an automatic closure of CHB-UV-523.
A
State the maximum letdown flow rate.
Do not exceed maximum design letdown flow rate of 150 gpm.