ERFDADS Flashcards

1
Q
What is the power supply to ERFDADS?
A.  PNA-D25
B.  PNB-D26
C.  NQN-D01
D.  NNN-D11
A

C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

While monitoring ERFDADS, the RO notes point SPDS0001 for Pressurizer Pressure is reading 1350 psia and is highlighted in white. Which of the following statements is true?
A. ERFDADS calculates this to be a good value
B. ERFDADS calculates this to be a suspect value
C. The value is out of range
D. The value has been manually inputted

A

B

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Containment Area Monitor RU-1 has an ALERT alarm.
The RO notes letdown flow is trending down, VCT level is trending down, and Pressurizer level is stable.
ERFDADS calculated RCS leakrate is 5 gpm and trending up.
The ERFDADS leakrate is currently ___(1)___ than actual leakrate. If the leakrate is stable, ERFDADS will have an accurate calculation in ___(2)___ minutes.
A. (1) less; (2) 7.5
B. (1) less; (2) 15
C. (1) greater; (2) 7.5
D. (1) greater; (2) 15

A

A

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

On September 1, Unit 1 reactor tripped. The STA saved the PTARS data in the SECONDARY file.
On September 7, Unit 1 reactor tripped. The STA did not save the PTARS data.
On September 12, Unit 1 reactor tripped. At this time, data in the STANDBY PTARS file is from ___(1)___ and data in the SECONDARY PTARS file is from ___(2)___.
A. (1) September 7; (2) September 1
B. (1) September 12; (2) September 1
C. (1) September 7; (2) September 12
D. (1) September 12; (2) September 12

A

B

How well did you know this?
1
Not at all
2
3
4
5
Perfectly