Book 29: CHAPTER 7 AIR RESCUE CUSHION Flashcards

1
Q

The Air Rescue Cushion employed by the Los Angeles City Fire Department is similar to air cushions used in the

A

movie industry.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

It is an inflatable cushion composed of a larger _____ ____ and a smaller _____ _____

A

Upper cell

Lower cell

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The cushion comes with two (______ hp) electric blowers.

A

One half horsepower

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Electricity for the blowers can be supplied by a variety of sources including the

A

Truck on-board generator or portable generator(s) and/or 110 supply (house current),.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

The Department currently has ___ Air Rescue Cushions, __rated at 100 feet and, __ rated at 70 feet.

A

24

6@100
18@70

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

The rating reflects the

A

Height of the jumper

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The assignment to a reported “jumper” consists of

A

One battalion chief
One task force
One paramedic rescue ambulance

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

If an Air Rescue Cushion is needed at an incident, it must be specifically asked for by the

A

Incident commander

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Who has 70 foot air cushions

A

2, 11, 17, 26, 27, 37, 48, 50, 60, 63, 64, 69, 70, 72, 85, 93, 94, 98

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Who has 100 foot airbags

A

10, 20, 58, 88, 95, recruit training

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

One of two situations will usually confront rescuers at a “jumper” incident:

A

Fire or industrial accident.

Or suicide jumper

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Industrial or fire accident:

the victim’s ability to respond to instructions may be limited by fear. Every attempt must be made by the rescuers to break through the _____ _____

A

Fear barrier

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Suicide jumper:

While attempting to open a line of communication, rescuers should attempt to confine the jumper to as small an area as possible. _____ room and ____ of area must be reduced.

A

Later room

And depth

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

A jumper should be “_____ ___” from as many sides as possible.

A

Closed on

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

The _______absorbs most of the energy generated by an impact.

A

Upper cell

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

It dissipates the energy by releasing air from the breather ports located on the ____ and ____ of the upper cell.

A

Side and front

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

The amount of air released is regulated by an _____ _____ ties over the breather ports.

A

Elastic chord ties

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

The lower cell does not have a _____ ____; consequently, very little air is released on impact.

A

Breather port

19
Q

Which cell has twice the energy-absorbing capabilities

A

Lower cell

20
Q

provides the safety margin for the air pack and determines the limiting height from which a person may safely fall.

A

Lower cell

21
Q

In less than ___ of a second, the Air Rescue Cushion is able to absorb and dissipate the energy of impact.

A

1/6

22
Q

The cushion is constructed of vinyl-reinforced fabric, which is?

A

Fire retardant and waterproof

23
Q

The tear strength of this material is over

A

50 pounds psi

24
Q

The seams of the cushion are sewn with a _________________which is stronger than the material of the cushion.

A

Heavy duty nylon thread

25
Q

The overall construction of the cushion makes it

A

Durable and resilient

26
Q

If the air cushion incurs minor damage, the ______ will easily compensate for the additional loss of air, and minor damage to the cushion might go unnoticed until it is inspected.

A

Blowers

27
Q

The air cushion rating is based on two factors:

  1. The maximum floor level from which a person may fall, based on _____ per floor, landing on the _____ or _____with a cushioning effect that is safely below the human tolerance level (as per the U.S. Air Force in “____________”).
  2. The ability of the person falling to properly hit the _____.
A

10 feet

Buttocks or back

Human tolerance to shock

Target

28
Q

DEPLOYMENT

  1. Move cushion and blowers to a
A

Pre deployment area

29
Q

For attempted suicide The blower should be

A

Out of view

30
Q

The preferred source of electricity is the

A

On board generator

31
Q

The on board generator has the capacity to run

A

Two blowers simultaneously

32
Q

_________ carried by Truck Companies do not have the capacity to start two blowers at the same time.

A

Portable generators

33
Q

The use of a _____ power supply is desirable, if possible. Remote power sources have the added advantage of greatly reducing ____ ____ at the incident, aiding ________ at the scene.

A

110 AC

noise levels
Communication

34
Q

If the on-board generator or other 110 AC power source is not available, two _____ _____ will be required to deploy the Air Rescue Cushion.

A

Portable generators

35
Q

As a last resort What cab be used to inflate the air cushion

A

Portable gasoline blowers

36
Q

The Air Rescue Cushion will fully inflate in less than

A

60 sec

37
Q

If two people must fall at the same time, they should

A

Hug each other

38
Q

Reinflation time

A

20 sec

39
Q

Never store the Air Rescue Cushion while

A

Wet

40
Q

Inspect the cushion after each use and

A

Monthly

41
Q

The cushion can be cleaned with

A

Cold water and a deck brush

42
Q

Air Cushion Model 70A

Size \_\_’ x \_\_’
Thickness _’
Rating \_\_th floor
Inflation Time\_\_\_\_
Re-inflation Time \_\_\_\_\_\_
Weight \_\_\_ pounds
Power Required \_\_\_\_ V AC
Blowers Two \_\_”, 1/2 HP, \_\_ HZ
Price $\_\_\_\_\_\_\_
A

15’x20’

8’

7th

1 min

20 sec

190lbs

115v ac

20” 60HZ

6,000

43
Q

Air Cushion Model 100A

Size \_\_’ x \_\_’
Thickness _’
Rating \_\_th floor
Inflation Time\_\_\_\_\_
Re-inflation Time \_\_\_\_\_
Weight \_\_\_\_ pounds
Power Required \_\_\_\_ V AC
Blowers One \_\_”, one \_\_”, 1/2 HP, 60 HZ
Price  $\_\_\_\_\_\_\_\_
A

20’x50’

9’

10th

1 min

20 sec

360lbs

115 v ac

20” 24”

8,500