BLOCK 4: CHEMICAL CONTROLS - Unit 17: Respirator Fit Testing (complete) Flashcards

1
Q

NOTE

I made this set ahead of the class schedule; I now know we are PTing in the lab with one of these procedures (Bitrex sensitivity) later this week. These cards may not be testable.

A

Here’s a cat to make your day better :)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

A pass/fail test method that uses a person’s sense of taste, smell, or irritation to determine whether facepiece leakage occurs. It requires no complicated equipment and can be done easily even in field conditions.

A

QUALITATIVE FIT TESTING (QLFT)

There are different methods to accomplish this type of fit testing. This unit will
describe the Bitrex solution protocols.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What are the items needed to perform a QLFT?

A
  • Test hood
  • Nebulizers
  • Sensitivity Solution
  • Fit Test Solution
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Needed to ensure the solution remains in the hood and around the subject’s breathing zone. This ensures the accuracy of the fit test.

A

FIT TEST HOOD

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Used to turn liquid test solution into an airborne mist. This airborne mist is introduced to the inside of the test hood to conduct the test.

A

NEBULIZER

Two nebulizers are used during QLFT. One is used for a sensitivity test and one is used for the fit test.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When conducting a qualitative fit test, you must first determine if the individual being fit tested is able to ___________________________________.

A

Footnote

DETECT THE TESTING SOLUTION

Without the ability to detect the testing solution, the worker
would be unaware if the respirator seal was leaking during the test.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

A ______________________ uses a machine to measure the number of particles inside and outside the mask and does not rely on the respirator wearer to taste or smell in order to detect a poor seal.

A

QUANTITATIVE FIT TEST (QNFT)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The degree to which the respirator fits the face of the wearer.

A

FIT FACTOR (FF)

Not to be confused with Assigned Protection Factor (APF) The FF is referring to performance as it is related to how the respirator fits the wearer, NOT the degree of protection it provides.
FF = APF x 10

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

QNFT must be accomplished when specified by an OSHA substance specific standard or when fit testing a negative pressure air-purifying respirator that must achieve a Fit Factor (FF) greater than ________.

A

100

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The purpose of QNFT for gas mask fit testing is: (three-fold)

A

–ENHANCE CBRN DEFENSE TRAINING
–HELP MAXIMIZE MASK PROTECTION
–INSTILL CBRN MASK CONFIDENCE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

The ____________________ (shown here), is an ambient aerosol condensation nuclei counter QNFT system used to perform fit testing. The Plus system can be used on respirators and gas masks.

A

PORTACOUNT PRO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Only __________ percent reagent grade isopropyl alcohol can be used in the wick assembly for the Portacount to operate as designed.

A

99.5%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

The ____________________ (shown here), is inserted in the Portacount and allows the system to count particulates.

A

WICK ASSEMBLY

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Two lengths of tube attach to the Portacount Pro. The shorter tube collects the ambient air and the longer tube attaches to the mask in order to draw air from inside the mask. The tubes together are referred to as the ____________________.

A

TWIN TUBE ASSEMBLY

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

TRUE OR FALSE:

The BE office will typically maintain a supply of gas masks and respirators for individuals to be fit tested.

A

TRUE

However, shop personnel should be encouraged to bring their individual respirators with them for fit testing.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

The purpose of the _________________________ is to position the drinking tube sampling port away from the user’s mouth.

A

SAMPLE TUBE EXTENDER

17
Q

The __________________________ is placed on the end of the drinking tube outside the mask and then attached to the twin assembly tube.

A

GAS MASK FIT ADAPTER

18
Q

__________________________ are required for fit testing respirators with the PortaCount. They are placed between the filter and the respirator in order to let the PortaCount sample the air inside the mask while being worn. It is removed after the fit test has concluded.

A

FIT TEST FILTER ADAPTERS

19
Q

An ______________________________ is used to generate particles in the air so the Portacount gets a good count from the ambient air and can detect if the particulates make it into the mask. Other ways to generate particles are to light a candle or spray an aerosol.

A

AEROSOL PARTICLE GENERATOR