apartment fires Flashcards
what are 2 big areas of concern for apartment fires
increased life hazard
potential for fire spread (230)
any significant fire upon arrival of the 1st unit should warrant the request of a ___
second alarm
a second alarm will be called for a fire involving ( 2 items)
more than 1 apartment
if fire has extended into the structural components of the building
apartments are typically built in combinations of __ __ and __ units per building
4,8,16
high priority must be given to search all apartments on or
above the fire floor (231)
the ic should assign crews to check all exposures for possible
victims and extension
t/f co can travel anywhere is the building and must be considered when evacuating occupants for the structure
true
regardless of the exterior façade the majority of apartments are composed of lightweight type ___ construction and they possess all of the dangers and concerns associated with this type of construction material
V
floors in apartments are generally composed of wood __ -___ material. most
I-joist
truss roof assemblies in apartments tend to be more stable than those in other types of structures due to the _______ both bearing and nonbearing
number of walls beneath them (232)
___ ventilation should still be done with caution and only if no substantial fire has entered the truss area
vertical
depending on the age of the apartment they typically have ___ plywood or wafer board sheathing supported by 2x4 rafters
1/2”
apartments tend to be __ because it is more economical for kitchens and bathrooms to share plumbing shafts
symmetrical
typically apartments on the same floor will ___ each other
mirror
true or false. although apartment symmetry is not always the case it is very common
true
builders prefer to share plumbing shafts for economical reasons resulting in most apartment and hotel kitchens and bathrooms being stacked. this creates __ __ that run the height of the building - ready avenues for extension
pipe chases
checking the __ __ for heat on the roof of an apartment fire is an indication that fire could be traveling up the chase
soil pipes
utilization of a___ is an effective way to check extension by it does not substitute for thorough overhaul. it may not give accurate conditions behind drywall
TIC
compromises in platform framing should be less of a problem in ___ which are built by lightweight methods, than in private dwellings
apartments (233)
apartments are required to have __ hour protection for each unit
1
compromises in platform framing should be more or less common in apartments
less
wood has an average ignition temp of ___ degrees
400
wood burns at a rate of 1” every __ min
40
mot apartments are not constructed of 2x4’s anymore rather they are composed of __ x __
1 1/2 x 3 1/2 or less
what ways are there to predict when floors or roofs are going to collapse
there are none
as a general rule once the room has ___ it can be assumed that the structural members are now being affected
flashed
gusset plate or gang nail is light gauge sheet metal with small nailing points protruding from it which penetrates the wood approximately __
1/4”
one of the most significant characteristics of the truss is that each piece of the truss will simultaneously be exposed to the __
fire (234)
the openness of the truss area is conducive to __ fire spread under the roof
lateral
engineered beams are formed with 2x4 top and bottom cords and laminated ___ as the web members
plywood
laminated I beams fail without warning in as little as __ min
5
glue in laminated I beams will cause the fire to burn __ and __
hotter and faster
normally if conditions in apartment fires allow for interior attack, structural collapse with not occur; however advanced fires that thwart entry can cause general __ __
total collapse
most bedrooms in apartments are no bigger than 12 x 12 which would only require __ gpm to control the fire quickly
48 (235)
glass breaks at about __ degrees
700
the size and design of most apartments make it ideal for ___ ventilation
PPV
most apartments are smaller than ___ sqft and cam be pressurized quickly
1000
PPV is not always feasible due to the size of the ____
landing
because attic spaces are divided by a __ __ at each apartment boundary, fire teams have an advantage in that area
fire draft (236)
in apartments if PPV is not available the inherently small area of most apartments can be ventilated quite effectively by opening the right ____
windows
streets within apartment complexes are generally narrow and some will be blocked by a ___ fire unit
single
incoming unit must be disciplined not commit to a position until
communicating with command
if a fire team that decides to vertically vent can approach from the top of ___ apartments
uninvolved
fire teams should not get into the habit of extending 1 3/4 inch lines farther than __ ft, as the nozzle flow will begin to reduce rapidly
250 (237)
for apartment located farther than __ ft away from the fire lane consider dropping 100-200 ft of 2 1/2 inch hose and wye off of that or use the 2 1/2” with the high rise pack and or a disconnected preconnect
100
when their are probable victims but their location is unknown the best rescue strategy is to
put out the fire
if resources are available , search, rescue, ventilation, and suppression operations should be conducted
simultaneously
beyond the immediate life hazard , all direct exposures should be ___ until the fire is under control
evacuated
the attic space above apartments is one large open area divided by
fire drafts
unless the fire team can observe the building while it is under construction they should assume that these fire separation have ___ often for phone or cable tv lines
pierced
will fire drafts slow or stop the fire
slow
fires in the attics of apartments should be vented form the top and attacked from ____
underneath (238)
if there is significant fire in the attic space of an apartment building, the officer may have to set their of defense over currently ___ apartment building.
uninvolved
fire that start in the attic often burn much ___ before they are reported than those that have extended into it
longer
never limit water flow when it is needed to put out the fire, but once the fire is out use water ____ and be keenly aware of leaking nozzles and hoses
sparingly