TP Flashcards
What 5 occasions will you receive a TPWS brake demand?`
Passed a signal at danger without authority
Travelling too fast approaching: signal at danger / buffer stops / PSR
Late to cancel AWS warning
If you have had an EBA not initiated by your own actions, what is the first thing you should check?
Brake Demand indicator on the TPWS panel to see if it is flashing red
If TPWS has initiated an EBA, what must you then do?
Stop and secure the train
Acknowledge by pressing the AWS button (on the standard panel)
Contact signaller immediately and inform them what has happened
Follow all instructions
Complete RT 3185 immediately
Do not move unless authorised by the signaller
How would a SPAD be indicated on
1. Standard TPWS panel
2. Enhanced TPWS panel
1 = Red flashing brake demand indicator
2 = SPAD indicator flashes red, audible alarm
How would an AWS late to cancel be indicated on
1. Standard TPWS panel
2. Enhanced TPWS panel
1 = Red flashing brake demand indicator, constant AWS audible alarm
2 = AWS indicator flashes yellow, constant AWS audible alarm
How would an Overspeed event be indicated on
1. Standard TPWS panel
2. Enhanced TPWS panel
1 = Red flashing brake demand indicator
2 = Overspeed indicator flashes yellow, audible alarm
How would you report a TPWS brake demand to the signaller?
“I have had a TPWS brake demand, due to xxxxx”
On a standard TPWS panel, what will happen to the brake demand indicator once you press the AWS button?
Goes steady red
On a standard TPWS panel, how long does the brake demand indicator stay illuminated if the AWS button is pressed?
60 seconds
On an enhanced TPWS panel, if you are late to cancel the AWS warning, how do you make the indicator go from flashing to steady yellow?
By pressing the AWS button
On an enhanced TPWS panel, how can you silence the audible warning for a SPAD and Overspeed, and what happens when you do this?
By pressing the relevant SPAD or Overspeed indicator…. The flashing indicator light goes steady when you do this
On an enhanced TPWS panel, how long will it take before you are able to reset the TPWS?
60 seconds
Whose permission must you have before resetting the TPWS?
Signaller (except approaching a buffer stop)
How do you reset the TPWS on:
1. Standard TPWS panel
2. Enhanced TPWS panel
1 = Brake release is obtained 60 seconds after acknowledging the EBA (by pressing the AWS button as appropriate)
2 = By pressing the Brake Release simultaneously with the appropriate SPAD/Overspeed indicator, after 60 seconds)
What forms do you complete immediately after a TPWS brake demand?
RT 3185
Incident report form