RQ-C-4864 (AFW) Flashcards

Auxiliary Feedwater

1
Q

What are the preferred suction sources for AFW listed in order

A

1) Affected Unit CST
2) Unaffected Unit CST
3) Affected Unit hotwell
4) ESW

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What happens in the AFW system as a result of a flow conservation signal

A
  • DCRs close (SG blowdown terminated)
  • AFW test valves close
  • AFW FMOs open
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Unit 1 was operating at 100% power with the East MDAFP OOS. 15 minutes ago a reactor trip was initiated due to a large steam break on SG 12. Given the following conditions:

The steam break has finished blowing down.
The SGSVs (MRV-210 & 240) for SG 11 and 14 closed as expected.
The SGSVs (MRV-220 & 230) for SG 12 and 13 failed to close.
Bus T11A is de-energized due to a fault experienced on the trip.

What is the only AFW supply (pump) that can be aligned to feed SGs 11 & 14?

A
  • U2 East MDAFP via crosstie (TDAFP no available due to SG 12 & 13 blowing down as a result of steam line break).
How well did you know this?
1
Not at all
2
3
4
5
Perfectly