RQ-C-4823 (Core Cooling and Inventory CSFST) Flashcards

1
Q

What condition(s) must be satisfied to exit FR-C-1 when re-establishing ECCS flow is unsucessful?

A

RVLIS NR above 46% or ANY of the 5 highest CETC less than 757 deg F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is the strategy behind depressurizing intact SGs to 160# in FR-C.1

A

Inject accumulators

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

How is accumulator nitrogen kept out of the RCS during FR-C.1

A

SG depressurization is stopped at 160# and 150# RCS pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

When are RCPs in loops with SG level started in FR-C.1

A

When the five highest CETCs are greater than 1200 deg F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How many RCPs are started in FR-C.1 when CETC are greater than 1200 deg F

A

Any RCP with a SG

How well did you know this?
1
Not at all
2
3
4
5
Perfectly