RQ-C-4841 (Excore Nuclear Instrumentation) Flashcards
Reactor power is 100%
Rod control is in manual
All other controls are in automatic
Which ONE of the following will cause the OverTemperature Delta-T trip setpoint to lower?
A) Lowering power to 50% with normal RCS pressure and temperature
B) N42 lower detector fails LOW
C) Auctioneered High Tavg fails LOW
D) RCS Wide Range Pressure channel fails LOW
B) N42 lower detector fails LOW
Unit 2 is at 100% power with all systems in automatic control when N44 fails high. What happens?
Rods move in automatically due to power rate mismatch.
Rods do not move back out (due to Tave < Tref) due to C-2 Rod Stop. Outward rod motion is blocked until the Rod Stop Bypass switch is placed in the N44 position.
Unit 2 is performing a startup with N41 taken out of service due to a failure. Then CRID 3 is lost. What happens?
Reactor trips due to 2/4 Power Range channels tripped (N43 also lost due to CRID III loss)
Describe what happens when NI instrument and control power fuses are pulled
Instrument - if placed in bypass nothing happens, otherwise channel goes to trip
Control - channel goes to trip since there is no bypass
In bypass, control power provides instrument power